4. 2 P repa rato ry Work on th e HS-1 80 Pla cemen t Stat ion NOTE If measurements are car ried out using UNIX machine data in mixed lines (HS / SIPLACE): The AutoCal program cannot convert the dat a previously m easured…

100%1 / 138
4.1.2 General Information About Handling Diskettes During Installation or Star-
ting From Diskette
The set of DD diskettes is used with computers that are not equipped with a hard disk.
If the station computer is equipped with an internal
hard disk
and one of the new HP printer, and if there is
enough storage space on the hard disk, you should
install
the AutoCal program as well as
all
driver pro-
grams that were delivered
and
the BASIC operating system onto the hard disk. Installation from diskette is
menu-controlled, as usual.
If the HS station computer (Placement Station/Adhesive Station II) or the computer of the MS machine uses
BASIC version 5.0
, the AutoCal program is
started from diskette. The same applies
if the computer is not
equipped with a hard disk, or if there is not enough storage space
on the internal hard disk. From AUTO_SMD
program version 106 onward it is possible to start the AutoCal software via the following menu option:
Starting programs from diskette.
If the computer is equipped with an HD-disk drive, installation diskette 1 (
HD
) must be used in order to avoid
unnecessary changing of diskettes.
Detailed information regarding handling of diskettes if the program is started from diskette is given in the
Flow chart, Fig. 4.1.
When
changing diskettes
it may occur that the first access to the diskette is unsuccessful when files are se-
arched for. In this event, the following message is displayed:
File not found: NAME
Pressing function key F8 "AGAIN" the file is searched for again and then found.
The "Version Description", chapter "Installation Instructions" contains further information with regard to
program installation.
4.1.3 Simple Handling of Diskettes Containing Printer Drivers (Operation Without
Hard Disk)
The driver for the Think-Jet printer is already contained on installation diskettes 1 (DD and HD set). If, how-
ever, a Desk-Jet printer is used and the AutoCal program is not run from a hard disk, the Think-Jet driver on
installations diskette 1 must be replaced by the Desk-Jet driver
before
the program is started. This
speeds
up
AutoCal procedures and avoids unnecessary changing of diskettes. Copying is performed on a computer
which is equipped with a hard disk:
1.
Insert the diskette containing the printer drivers.
2.
Copy file "DST" from the diskette to the hard disk.
3
. Insert installation diskette 1.
4.
Delete file "DST" on installation diskette 1.
5.
Copy file "DST" from the hard disk to the diskette.
6.
Delete "DST" from the hard disk.
4 Preparatory Work to be Performed Before (up to and including) the Start of the Calibration Procedure User’s Manual AutoCal Program
4.1 Sets of Diskettes / Handling of Diskettes Software Version 114.xxx
4 - 2
4.2 Preparatory Work on the HS-180 Placement Station
NOTE
If measurements are carried out using
UNIX
machine data in mixed lines (HS / SIPLACE): The AutoCal
program cannot convert the data previously measured using BASIC. Therefore the machine measure-
ments must be re-determined
completely anew
. Please contact Siemens AG SMD-Service.
4.2.1 Checking MA Data Before Copying them to the Work Diskette
Before copying, the machine data must be checked on the line computer:
On the whole, the MA-data must already have been entered correctly within narrowly defined limits.
In the case of UNIX machine data, only
one
reject position may be entered for the AutoCal procedure
(either "reject box at nozzle changer " or "CRDL/Vacuum reject"). This must be changed back after the
measured data have been copied to the master data storage!
On principle, the entered (activated) options must be consistent with the options installed on the machi-
ne which are to be measured. Since the activation of options can be changed only on the line compu-
ter, it must be corrected before the MA-data are copied.
A blank,
properly formatted work diskette
with deactivated write protection tab must be available for
copying MA-data for the
UNIX and BASIC
line computers.
NOTE
The write-protection tab of the AutoCal program diskette must not be removed. Saving data to the pro-
gram diskette is
not permitted
!
4.2.2 BASIC Line Computer: Copying Files to the Work Diskette
NOTE
This description applies to systems from version LBR 10
2
.xxx. If you still work with line computer soft-
ware
<
102.xxx you should order an
update !
Please note: If the data format has not changed, it may be that the BASIC line computer does not auto-
matically modify the version string (e.g. when updating from LBR.102 to LBR.208).
The new version entry (replacing V2.01 by V2.09) can be done by saving the MA-data on the BASIC line
computer station-by-station.
An overview of the file versions is contained in section 1.4.1.
The PASSPKT file is required only if in the course of mapping you wish to load the old mapping data for
comparison measurements.
The MA_ZUSATZ file must be saved to the work diskette only if the "coplanarity" option is available and
activated in the MA-data.
Please enter the special password and copy the MA-data of the line you wish to calibrate onto an
HP
-for-
matted, blank
3.5" diskette (= work diskette). This procedure is menu-controlled.
Proceed as described in section
4.2.4
or
4.2.5
.
User’s Manual AutoCal Program 4 Preparatory Work to be Performed Before (up to and including) the Start of the Calibration Procedure
Software Version 114.xxx 4.2 Preparatory Work on the HS-180 Placement Station
4 - 3
4.2.3 UNIX Line Computer: Copying Data to the Work Diskette
Using the Data Manager, copy the MA-Data ("_.sk" and "_.kd" files) of the line you wish to calibrate onto a
DOS-formatted, blank 3.5" diskette (= work diskette).
The "_.SRP" file is only required if you wish to carry out comparison measurements with respect to these data.
Proceed as described in sections
4.2.4
or
4.2.5
.
4.2.4 Station computer: Installing the AutoCal Program Onto the Hard Disk
Switch off the machine.
Insert
installation diskette 1
into the disk drive of the station computer.
Switch the machine back on again while the control unit remains in
off
position!
After a short while, the "ABORT" key (function key) is displayed on the screen. Press this key within 8 se-
conds ( 1 second corresponds to 1 asterisk, shown in the lower right corner of the screen).
Select the "
Installation from diskette
" option on the menu displayed.
Now proceed with the menu-controlled installation of the AutoCal program.
Proceed as described in sections
4.2.5
"HS-180 Checklist" and
4.2.6
"Starting....from the Hard Disk".
4.2.5 HS-180 Checklist: Ensuring that the Prerequisites for Program Start are Met.
1.
The machine must be in
optimum
operating condition in order to avoid any disturbing interference and
unnecessary expenditure of time during the calibration procedure.
2.
All machine data of the station must already be correct within narrowly defined limits.
3.
The options installed must be
activated
in the MA-Data (cannot be changed in the Edit menu!).
Ensure
correct activation of nozzle changer/adapter station
!
4.
All testing aids must be on hand.
5.
The temperature requirements for steel mapping must be met (see chapter 5, section 5.1.8).
6.
The keyswitch must be
removed
(see chapter 2).
7.
The work diskette with the MA-data of the station must be inserted in the disk drive, with the write
protection tab deactivated.
8.
The printer (where available) and the teach panel must be connected to the system.
9.
The printer must be provided with sufficient paper (paper end during measurement routine = malfunction!).
10.
All installed line extensions must be switched ON, but must not have been initialized yet.
Line extensions
:
Input/output station, waffle-pack changer, waffle-pack changer at IC shuttle, IC shuttle.
11.
All axes must be switched on at the axis controller cards (check switch position!)
4 Preparatory Work to be Performed Before (up to and including) the Start of the Calibration Procedure User’s Manual AutoCal Program
4.2 Preparatory Work on the HS-180 Placement Station Software Version 114.xxx
4 - 4