00190725-01.pdf - 第32页

3.4 Prer equi sites f or M S-10 2, MS-12 8 an d MS -132 3.4. 1 Syst em Req uirem ents • Winchester • Interf ace Software V 2.5 and higher • Station Software from MSX.200.xxx • Axis Car d Software Ver sion 2.5 and higher …

100%1 / 138
3.3 Prerequisites for HS-180 Adhesive Application Station II
3.3.1 System Requirements
Computer, series 362 with one HD disk drive or
Computer 200 with DD or HD disk drive or
Computer 310, 332 with HD twin floppy disk drive or DD disk drive
HS-180 Interface Software Version 2.3 and higher,
Line/Station Software from Version 2.01 (see following NOTE) *
Axis Card Software Version 1.8 and higher
BASIC from V5.0
*
The version to be used is selected by the operator in the Machine Selection Menu
NOTE:
Adhesive Station
I cannot
be measured with the AutoCal program!
The new HP printer requires the use of BASIC Version 6.21.
This version is delivered along with the AutoCal program (see Chapter 4, "Set of Diskettes").
If the
LRB <102.xxx version
is still used on the line computer, please order an update!
3.3.2 Testing Aids
AutoCal program, available on 2 different sets of diskettes:
AutoCal program on 5 DD diskettes, item no. 00322032
AutoCal program on 4 DD diskettes and 1 HD diskette, item no. 00322032
(For details please refer to chapter 4. Supply source see page 3-2)
NOTE
The following testing aids must be available for the performance of the Routine Check (all measuring rou-
tines are carried out). For individual checks, only the testing aids listed in chapter 8 are required.
The following testing aids are delivered with the machine:
MA-zero point insert for adhesive station II, item no. 02102407
Parts to be ordered:
New MA-zero point gauge (with 2 holes: 3.5 mm and 5 mm), item no. 00120060
1)
Glass mapping plate, included in the Glass Mapping Case, item no.: upon request.
1)
Only
one
MA-zero point gauge is required for calibrating
all
stations of
all
lines!
Additionally required testing aids:
Plasticine
A work diskette must also be provided
BASIC line computer: One blank HP formatted 3.5" diskette, write protection tab deactivated.
User’s Manual AutoCal Program 3 Requirements for Use
Softwareversion 114.xxx 3.3 Prerequisites for HS-180 Adhesive Application Station II
3 - 3
3.4 Prerequisites for MS-102, MS-128 and MS-132
3.4.1 System Requirements
Winchester
Interface Software V 2.5 and higher
Station Software from MSX.200.xxx
Axis Card Software Version 2.5 and higher
BASIC from version 6.0 (contained on the hard disk/Winchester)
NOTE:
The new HP printer requires the use of BASIC Version 6.21.
This version is delivered along with the AutoCal program (see chapter 4, "Set of Diskettes").
3.4.2 Testing Aids Required
AutoCal program, available on 2 different sets of diskettes:
AutoCal program on 5 DD diskettes, item no. 00322032
AutoCal program on 4 DD diskettes and 1 HD diskette, item no. 00322032
(For details refer to chapter 4. Supply source - see below)
NOTE
The following testing aids must be available for the performance of the Routine Check (all measuring rou-
tines are carried out). For individual checks, only the testing aids listed in chapter 9 are required.
The following testing aid are delivered along with the machine:
Steel nozzle, type 104, item no. 00301435
New MA-zero point gauge (with 2 holes: 3.5 mm and 5 mm), item no. 00120060
New adjusting gauge for component table ("iron", with 2 holes), item no. 00120040
Adjusting gauge for adhesive application head, with tip, item no. 00310314
Teach panel, external, item no. 00132207
Calibrating nozzle for coplanarity module, item no. 00301711
VISION 2 Calibration plate, item no. 00132070
2 Test sockets for nozzle changer
*)
:
Large test socket (for special holder), item no. 00311659
Small test socket (for normal holder), item no. 02102021
Nozzle top part = nozzle insert, item no. 00302566
*)
*) also included with nozzle changer accessories kit
Parts to be ordered:
Nozzle adapter, type 117, item no. 00300659
Mapping plate and centering square for MS-102/128, contained in the Mapping Case, item no. 00132040
Mapping plate and centering square for MS-132, contained in the Mapping Case, item no. 00134100
3 Requirements for Use User’s Manual AutoCal Program
3.4 Prerequisites for MS-102, MS-128 and MS-132 Softwareversion 114.xxx
3 - 4
Additionally required testing aids:
Plasticine
Supply source: Siemens AG
AUT 5 V Service
Rupert-Mayer-Str. 44
D-81359 München
Tel. 089/722 61200
FAX: 089/722 24260
User’s Manual AutoCal Program 3 Requirements for Use
Softwareversion 114.xxx 3.4 Prerequisites for MS-102, MS-128 and MS-132
3 - 5