3 Require men ts for Use NOTE The s ystem supports the HP Think-Jet printer at the HPI P bus and the new HP 560C Desk-J et printer at the parallel bus (printer drivers see section 4.1.1). The printer is an optional equip…
This page intentionally left blank.
2 Safety User’s Manual AutoCal Program
2.4 Safety Requirements During the Performance of the I/O Menus SoftwareVersion 114.xxx
2 - 4

3 Requirements for Use
NOTE
The system supports the HP Think-Jet printer at the HPIP bus and the new HP 560C Desk-Jet printer at
the parallel bus (printer drivers see section 4.1.1). The printer is an optional equipment of the machine.
The new HP printer requires BASIC version 6.21.
This version is part of the AutoCal program’s scope of delivery (see Chapter 4, section "Set of diskettes").
3.1 Information About Working with UNIX/BASIC Machine Data (HS-180)
The BASIC machine data can no longer be used with the new UNIX line computer.
— Therefore the AutoCal program provides the possibility to work both with BASIC and UNIX machine data.
The AutoCal program can "recognize" whether the MA-data are written in UNIX or BASIC format. The re-
spective files are read in.
— A prerequisite for processing UNIX machine data is the use of BASIC version 6.x or higher, since DOS
diskettes can be read only from this version onwards.
NOTE
When measuring is performed using UNIX machine data on mixed lines (HS/SIPLACE), the following app-
lies: The AutoCal program cannot convert the data previously measured using BASIC. Therefore the machine
measurements must be re-determined completely anew. Please contact Siemens AG SMD-Service.
3.2 Prerequisites for HS-180 Placement Stations
3.2.1 System Requirements
• Computer, 362 series with one hard disk drive or
• Computer 200 (DD-disk drive) or
• Computer 310, 332 with HD twin-floppy disk drive or DD disk drive
• HS-180 Interface Software Version 2.3
• Line/Station Software from version 2.01 (see table, section 1.4.1)
• Axis Card Software Version 1.8 and higher
• HS-180 with UNIX line computer: BASIC from version 6.x
* The version used will be selected by the user in the Machine Selection Menu (see section 1.4.1).
NOTE:
On the newer HS-180 machines with HF-structured hard disks the drive may have the address "703,1".
This drive is supported by the AutoCal program (from V111.03).
If LRB <102.xxx is still used on the line computer, you should obtain an update!!
Overview "Line Computer Software Version / MA File Version" can be found in Section 1.4.1.
User’s Manual AutoCal Program 3 Requirements for Use
Softwareversion 114.xxx 3.1 Information About Working with UNIX/BASIC Machine Data (HS-180)
3 - 1

3.2.2 Testing Aids Required
• AutoCal program, provided on 2 different sets of diskettes:
—
AutoCal program on 5 DD diskettes, item no. 00322032
—
AutoCal program on 4 DD diskettes and 1 HD diskette, item no. 00322032
(For details please refer to Chapter 4. Supply source: see below)
NOTE
The following testing aids must be available for the performance of the Routine Check (all measuring rou-
tines are performed). For individual checks, only the testing aids listed in chapter 7 are required.
The following testing aids are delivered with the machine:
• Steel nozzle, type 104, item no. 00301435
• Teach panel, external, item no. 00132207
• Calibrating nozzle for coplanarity module, item no. 00301711
• 2 test sockets for nozzle changer:
test socket for special holder (= large), item no. 00311659
*)
test socket for normal holder (= small), item no. 02102021*)
• Nozzle top part = nozzle insert, item no. 00302566
*)
contained in the nozzle changer accessories kit
The following testing aids must be ordered extra:
• Nozzle adapter, type 117, item no. 00300659
• New MA-zero point adjusting gauge (with 2 holes: ∅ 3.5 mm and ∅ 5 mm), item no. 00120060
1)
• New adjusting gauge for component table ("iron", with 2 holes), item no. 00120040
2)
• Mapping plate (for steel mapping) and centering square, included in the Mapping Case, item no. 00132040
• Glass mapping plate, contained in Glass Mapping Case, item no.: upon request.
• VISION 2 Calibration plate, item no. 00132070
1)
One
MA-zero point gauge is required for calibrating
all
stations of
all
lines!
2)
One
adjusting gauge is required for calibrating
all
stations of
one
line!
CAUTION
∆
!
The temperature of the steel mapping plate must have the
same temperature as the machine
before any
measurements are carried out
!
Further details see description of menu option "Mapping Menu" in chapter
5.
Furthermore, a work diskette must be provided.:
• For UNIX line computers: One blank 3.5" diskette: DOS-formatted, no sub-directories, write protection tab
deactivated.
• For BASIC line computers: One blank HP-formatted 3.5" diskette, write protection tab deactivated.
Supply source:
Siemens AG Tel. 089/722 61200
AUT 5 V Service FAX: 089/722 24260
Rupert-Mayer-Str. 44
D-81359 München
3 Requirements for Use User’s Manual AutoCal Program
3.2 Prerequisites for HS-180 Placement Stations Softwareversion 114.xxx
3 - 2