00190725-01.pdf - 第67页

6 Interd epen dent C alibrat ion s Requi red fo r I ndividua l Checks DANGER ∆ ! ∆ ! ∆ ! DANGE R OF ACCIDE NT / DAN GER OF PLACEM ENT HE AD CRASH D UE TO INCORR ECT HAN DLING Adhere to the safety instructions contained i…

100%1 / 138
This page intentionally left blank!
5 Description of the Menu Options User’s Manual AutoCal Program
5.3 Description of the Menu Options for MS-102, 128 and 132 Software Version 114.xxx
5 - 24
6 Interdependent Calibrations Required for Individual
Checks
DANGER
!
!
!
DANGER OF ACCIDENT / DANGER OF PLACEMENT HEAD CRASH DUE TO INCORRECT HANDLING
Adhere to the safety instructions contained in chapter 2.
Individual checks are used within the scope of given service activities (e.g. after installation/reinstallation
of the component camera/placement head) and, as the case may be, for fault isolation procedures. Pre-
requisite for working with the AutoCal program for the performance of individual checks is the knowledge
about safety hazards in special situations and the functional interrelationships on the machine.
6.1 Overview
Certain MA-Data and therefore certain calibrations are interdependent.
With some MA-Data this dependency differs between HS and MS-machines !
As is the case with the Routine Check, the following prerequisites must be fulfilled for the individual
checks as well:
The MA-Data must already be correct within narrowly defined limits (incl. head height and activation of
the installed options).
The basic settings (e.g. jaws adjustment, axis adjustment, zero point correction of the axes) must be
correct.
The machine must have been properly serviced.
Depending on the machine type used, proceed according to the following sections:
for HS-180 placement machines: section 6.2, Figs. 6.1 and 6.3,
for HS-180 adhesive station II: section 6.3, Fig. 6.4,
for MS-machines: section 6.4, Figs. 6.5 and 6.6.
NOTE
When converting to software version V2.03 (LRB.2xxx.xxx) it is required that a hardware conversion from
ICOS II to ICOS IIQ be performed. Within the scope of this conversion, the PCB vision and component
vision systems as well as the coplanarity laser module must be re-calibrated.
User’s Manual AutoCal Program 6 Interdependent Calibrations Required for Individual Checks
Software Version 114.xxx 6.1 Overview
6 - 1
6.2 Interdependent Calibrations on the HS-180 Machine
Further interdependent calibrations on the HS-180 are indicated on the following page!
**)
Fig. 6.1 Interdependend Calibrations on HS-180 Placement Stations
6 Interdependent Calibrations Required for Individual Checks User’s Manual AutoCal Program
6.2 Interdependent Calibrations on the HS-180 Machine Software Version 114.xxx
6 - 2