10.1. 2 Applie s t o sof tware versi on 2.0 1 (LRB 1 XX.xxx) on the BASI C line c ompu ter: Readin g in t he PA SSPKT_ file: • Insert the work dis kette cont aining the MA-data int o the disk drive of t he line computer.…

10 Final Work After Calibration
This chapter describes all activities to be performed after the completion of the AutoCal measuring procedure.
Proceed in accordance with the applicable section listed below (10.1: HS-180 / 10.2: Adhesive Station II /
10.3: MS-1xx).
10.1 Final Work on HS-180 Placement Stations
10.1.1 On the BASIC Line Computer (from LRB 102.xxx): Loading the Files
Copy the MA_DATEI and, if applicable, the MA_ZUSATZ file with the new values and the PASSPKT_ file
created during mapping, from the work diskette to the hard disk of the line computer proceeding as descri-
bed below:
•
After "STORING" and completed calibration, remove the
work diskette
containing the created or
modified files, from the disk drive of the station computer and take the diskette to the line computer.
•
Enter the appropriate password on the line computer.
•
Starting from the main menu, select "File Functions" on the line computer.
•
Insert the work diskette containing the new data into the disk drive.
•
Copy the two files MA_DATEI and MA_ZUSATZ of the calibrated station from the work diskette to the
hard disk of the line computer by pressing successively the following function keys:
File function
→
Copy
→
Copy file
→
Next menu
→
System files
→
MA_ of station
→
Station 1 or
Station 2
→
System files
→
MA_ZUSATZ
→
read in file of the calibrated station).
NOTE
In the case of software version 2.01 (from LRB 102.xxx onward) proceed as described in the follo-
wing section, as the PASSPKT_ file is to be renamed before being read in and subsequently to be
changed back to the original name again.
•
From LRB 204.xxx onwards, save the new mapping file (PASSPKT_file) on the line computer, as follows:
File function
→
read in RP_files
→
Station 1 / Station 2.
•
Wait until the disk drive indicator lamp is extinguished.
•
Remove the work diskette from the disk drive.
User’s Manual AutoCal Program 10 Final Work After Calibration
Software Version 114.xxx 10.1 Final Work on HS-180 Placement Stations
10 - 1

10.1.2 Applies to software version 2.01 (LRB 1XX.xxx) on the BASIC line computer:
Reading in the PASSPKT_ file:
•
Insert the work diskette containing the MA-data into the disk drive of the line computer.
NOTE
The created PASSPKT_* file (* = station no.) must be renamed before it is saved to the line computer.
•
Rename the new PASSPKT_ file before it is read into the line computer by executing the
following sequence of commands:
NOTE
"X" denotes the no. of the station.
Example of a line configuration comprising 1x adhesive station, 1x SP-120, 2x HS-180:
1. HS-180 Station: X =
3
2. HS-180 Station: X =
4
• RENAME "PASSPKT_X:,703,1" TO "PASSPKT:,703,1"
• CONT
•
Starting from the main menu on the line computer select "File Functions" and thereafter
"Read RP-files". Enter the no. of the station (see note above). The new data
are saved to the hard disk. Pay attention to the following NOTE.
NOTE
After the PASSPKT file has been read in (on the hard disk) its name must be changed back to the origi-
nal name so that it will not be overwritten when the PASSPKT_ file of another station is read in.
Example: RENAME "PASSPKT:,703,1" TO "PASSPKT_3:,703,1"
•
Wait until the disk drive indicator light is extinguished. Then remove the work diskette.
10 Final Work After Calibration User’s Manual AutoCal Program
10.1 Final Work on HS-180 Placement Stations Software Version 114.xxx
10 - 2

10.1.3 On the UNIX Line Computer: Loading the Files, incl. "_ .SRP"
•
After "STORING" and completed calibration, remove the
work diskette
containing the created or modified
files, from the disk drive of the station computer and take the diskette to the line computer
•
Insert the diskette into the disk drive of the line computer.
•
Using the Data Manager copy the new MA-Data to the master data storage, proceeding as follows:
Data Manager: DOS (e.g. "1.44MB", depending on formatting) ---> Data Manager: Master Data: Stations:
<Station name>.st.
NOTE
At present, the File Manager copies the
mapping file "_.SRP"
to the master data storage as "
.srp
"
file. This can be corrected by simply renaming (move file) the file from " .srp" to " .SRP". (File designa-
tion "
_
. " only on DOS diskettes, on the UNIX line computer the file designation is "
.
" ).
If too many files are contained in the station directory, the message "File cannot be copied" may be
displayed. Correct this by deleting files that are
no longer
required (File - Delete).
•
First delete the
" _.SMA"
file from the master data storage as otherwise this file will not be recompiled
and therefore not contain the latest update of the data.
NOTE
Compiling and deleting the files is not possible if a placement cycle was started.
•
Subsequently compile the read-in files:
Data Manager: Master Data: Stations: <Station name>.st
→
Select menu option "Compile".
•
If prior to copying the MA-Data two reject positions were entered on the line computer (for the AutoCal run
the number of reject positions needed to be changed to one!), those
two
reject positions must be
entered
again before the station software is started!
10.1.4 Final Work Before Starting the Station Software
•
Establish the
reference status of the nozzle changer HS-180
(hardware/software compatibility):
•
The nozzle insert must remain installed for the placement cycle that follows.
•
No nozzle may have been picked up by the placement head nor have been installed manually!
•
All nozzle types (allocation to be looked up on the line computer) must be inserted in the nozzle chan-
ger - their proper allocation
to the respective location no. having been observed!
User’s Manual AutoCal Program 10 Final Work After Calibration
Software Version 114.xxx 10.1 Final Work on HS-180 Placement Stations