00190725-01.pdf - 第131页
10.1. 3 On th e UNI X Lin e Co mputer : Lo ading t he Fil es, incl. " _ . SRP" • After " STORING" and completed calibration, r em ove the work di skette containing t he created or modified files, from…

10.1.2 Applies to software version 2.01 (LRB 1XX.xxx) on the BASIC line computer:
Reading in the PASSPKT_ file:
•
Insert the work diskette containing the MA-data into the disk drive of the line computer.
NOTE
The created PASSPKT_* file (* = station no.) must be renamed before it is saved to the line computer.
•
Rename the new PASSPKT_ file before it is read into the line computer by executing the
following sequence of commands:
NOTE
"X" denotes the no. of the station.
Example of a line configuration comprising 1x adhesive station, 1x SP-120, 2x HS-180:
1. HS-180 Station: X =
3
2. HS-180 Station: X =
4
• RENAME "PASSPKT_X:,703,1" TO "PASSPKT:,703,1"
• CONT
•
Starting from the main menu on the line computer select "File Functions" and thereafter
"Read RP-files". Enter the no. of the station (see note above). The new data
are saved to the hard disk. Pay attention to the following NOTE.
NOTE
After the PASSPKT file has been read in (on the hard disk) its name must be changed back to the origi-
nal name so that it will not be overwritten when the PASSPKT_ file of another station is read in.
Example: RENAME "PASSPKT:,703,1" TO "PASSPKT_3:,703,1"
•
Wait until the disk drive indicator light is extinguished. Then remove the work diskette.
10 Final Work After Calibration User’s Manual AutoCal Program
10.1 Final Work on HS-180 Placement Stations Software Version 114.xxx
10 - 2

10.1.3 On the UNIX Line Computer: Loading the Files, incl. "_ .SRP"
•
After "STORING" and completed calibration, remove the
work diskette
containing the created or modified
files, from the disk drive of the station computer and take the diskette to the line computer
•
Insert the diskette into the disk drive of the line computer.
•
Using the Data Manager copy the new MA-Data to the master data storage, proceeding as follows:
Data Manager: DOS (e.g. "1.44MB", depending on formatting) ---> Data Manager: Master Data: Stations:
<Station name>.st.
NOTE
At present, the File Manager copies the
mapping file "_.SRP"
to the master data storage as "
.srp
"
file. This can be corrected by simply renaming (move file) the file from " .srp" to " .SRP". (File designa-
tion "
_
. " only on DOS diskettes, on the UNIX line computer the file designation is "
.
" ).
If too many files are contained in the station directory, the message "File cannot be copied" may be
displayed. Correct this by deleting files that are
no longer
required (File - Delete).
•
First delete the
" _.SMA"
file from the master data storage as otherwise this file will not be recompiled
and therefore not contain the latest update of the data.
NOTE
Compiling and deleting the files is not possible if a placement cycle was started.
•
Subsequently compile the read-in files:
Data Manager: Master Data: Stations: <Station name>.st
→
Select menu option "Compile".
•
If prior to copying the MA-Data two reject positions were entered on the line computer (for the AutoCal run
the number of reject positions needed to be changed to one!), those
two
reject positions must be
entered
again before the station software is started!
10.1.4 Final Work Before Starting the Station Software
•
Establish the
reference status of the nozzle changer HS-180
(hardware/software compatibility):
•
The nozzle insert must remain installed for the placement cycle that follows.
•
No nozzle may have been picked up by the placement head nor have been installed manually!
•
All nozzle types (allocation to be looked up on the line computer) must be inserted in the nozzle chan-
ger - their proper allocation
to the respective location no. having been observed!
User’s Manual AutoCal Program 10 Final Work After Calibration
Software Version 114.xxx 10.1 Final Work on HS-180 Placement Stations
10 - 3

•
In the case of existing UNIX Machine Data: Change, if necessary, the reject positions in the MA-Data of
the line computer back from one position to two positions, provided this corresponded to the entry that exi-
sted prior to the start of the AutoCal program run.
•
If necessary, also determine the X,Y and Z-positions of the mechanical centering station and the adapter
station, proceeding as described in the Service Manual.
10.2 Final Work on HS-180 Adhesive Station II
10.2.1 BASIC line computer (from LRB 102.xxx): Loading the Files
Read in the MA_DATEI containing the new values and the PASSPKT_ file created during mapping, by loa-
ding them from the work diskette to the hard disk of the BASIC line computer, as described for the HS-180 in
section 10.1.1.
10.2.2 Unique to Software Version 2.01 (LRB 1XX.xxx) on BASIC Line Computers:
Reading In the PASSPKT_ File
The PASSPKT_ file is to be read in and renamed prior to and after being copied to the BASIC line computer,
proceeding as described for the HS-180 in section 10.1.2.
CAUTION
∆
!
The compressed air for the dispensing stroke was reduced to 3 bar for the AutoCal program run!
Now - prior to the start of the station software - readjust the compressed air for the dispensing stroke
(right-hand pressure gauge) to the previously adjusted value (3.5 bar) ! Lock the machine base door.
Reinstall both adhesive cartridges in their proper positions!
10 Final Work After Calibration User’s Manual AutoCal Program
10.2 Final Work on HS-180 Adhesive Station II Software Version 114.xxx
10 - 4