11 Malfunctions in the Program Sequence
When working with the AutoCal program it may happen that the computer "locks up" due to invalid changes /
entries.
Possible Causes:
• If the printer is connected during the measuring routine.
• On MS-machines: Interface card is installed but its cable is not connected to the computer or the interface
card is not activated in the MA-Data.
At this stage different possibilities are described in the following that enable you to continue with your work.
11.1 Troubleshooting on HS-180 Placement Stations / Adhesive Station II
WARNING
∆
!
∆
!
As a first step in this situation, press the EMERGENCY STOP button and thereafter remove all testing
aids such as mapping plate or MA-zero point gauge, etc. that may have been left in the machine.
Restarting the program after resetting: computers from series 200 onwards
•
With the SHIFT key pressed, simultaneously press the PAUSE key.
•
Press RUN (function key): The program is restarted.
Restarting the program after resetting: computers from series 300 / 362 onwards
•
With the SHIFT key pressed, simultaneously press the RESET button.
•
Press RUN (function key): The program is restarted.
Hardware Reset
•
Turn main switch OFF and back ON again: restart of the AutoCal program from diskette or hard disk.
User’s Manual AutoCal Program 11 Malfunctions in the Program Sequence
Software Version 114.xxx 11.1 Troubleshooting on HS-180 Placement Stations / Adhesive Station II
11 - 1

11.2 Troubleshooting on MS-102, 128, 132 Machines
WARNING
∆
!
∆
!
As a first press in this situation, press the EMERGENCY STOP button and thereafter remove
all
testing
aids such as mapping plate or MA-zero point gauge, etc. that may have been left in the machine.
Restarting the program after resetting: computers from series 300 onwards
•
With the
SHIFT key
pressed, simultaneously press
RESET
.
•
Press
RUN
(function key): The program is restarted.
Hardware Reset
•
Turn main switch
OFF
and back
ON
again: restart of the AutoCal program from diskette or hard disk.