5.2 Descr ipti on of t he Men u Opt io ns fo r H S-180 Adhesi ve S tati on II 5.2. 1 ED IT MEN U After selecting the "EDIT MENU" the submenu appears (see Fig. 1.6). The desc ription of t his menu is cont ained …

100%1 / 138
TEST INPUTS
After selecting "TEST INPUTS" the following screen appears.
SIEMENS CALIBRATION PROGRAM AutoCal 114.xxx
STATION 1 ----------------------------------------------------------------------------------------------------------------------
TEST INPUTS
EF821.1=1 EF821.1=0 EF821.1=1 EF821.1=0 EF821.1=0
EF821.1=0 EF821.1=1 EF821.1=0 EF821.1=1 EF821.1=0
EF825.5=1 EF825.5=0 EF825.5=1 EF825.5=0 EF825.5=0
EF824.7=1
In the view area, which is delimited by two lines, all changes of the status changes of the inputs are dis-
played. Use function key f1 for "CLEAR DISPLAY" to delete the inputs displayed.
5.1.22 STORING
The values determined can be saved from the main memory to the work diskette by selecting this menu opti-
on available on the main menu and the EDIT menu.
A save should be performed after each measuring routine so as to preclude any data loss due to any malfun-
ctions that might occur.
If the work diskette containing the machine data is write protected, the software will issue the following mes-
sage after "STORING" has been selected:
"NO SPACE TO STORE".
This is, however, not the case. Deactivate the write protect tab on the work diskette and select "STORING"
once more.
CLEAR
DISPLAY
END
User’s Manual AutoCal Program 5 Description of the Menu Options
Software Version 114.xxx 5.1 Description of the Menu Options for HS-180 Placement Stations
5 - 13
5.2 Description of the Menu Options for HS-180 Adhesive Station II
5.2.1 EDIT MENU
After selecting the "EDIT MENU" the submenu appears (see Fig. 1.6).
The description of this menu is contained in section 5.1.1
5.2.2 CHECK AXIS ADJUSTMENT
The description of this menu option is contained in section 5.1.2
On the Adhesive Station II the axis adjustment test for the X and Y-axes is possible.
5.2.3 MEASURE MACHINE ZERO POINT
This measuring routine is used to determine the X and Y-zero point
correction
values of the MA zero point.
Just as is the case on other machines, this is carried out by means of the MA zero point gauge. For the pur-
pose of this measuring routine, the adhesive station zero point gauge is installed in the adhesive application
head in lieu of the right adhesive cartridge.
The description of this menu option is contained in section 5.1.3
Pay attention to the WORKAROUND pertaining to this menu option section 12.3
5.2.4 PCB EDGE FIXED TABLE
This measuring routine is used to determine the "PCB EDGE FIXED TABLE Y" value. To this end, first the
Bero switching point is determined and is then displayed on the screen together with the internally calculated
"PCB EDGE FIXED TABLE " value.
The "PCB EDGE FIXED TABLE " value is required within the scope of the AutoCal measuring sequence as
well as during the placement cycle as starting value (see description of this menu option in section 5.1.7.
5.2.5 MAPPING MENU
Mapping is used for the automatic measurement of the gantry offset.
The Mapping menu is only offered if a head camera is activated on the Adhesive Station II.
Mapping is carried out by measuring the
glass
mapping plate.
Prior
to the
glass
mapping sequence the
head camera
must be
calibrated
(see menu options 5.2.7 and
5.2.8) !
After selecting the "Mapping menu" a
submenu
(see Fig. 1.7) is displayed.
Carry out the menu functions proceeding in the sequence as shown on the screen
.
5 Description of the Menu Options User’s Manual AutoCal Program
5.2 Description of the Menu Options for HS-180 Adhesive Station II Software Version 114.xxx
5 - 14
Please not the following:
For the glass mapping process both adhesive cartridges and also the MA zero point gauge required
for other Adhesive Station II routines must be removed!
DANGER OF DAMAGE: Pay attention to the DANGER note in the sequence description, chap. 7!
The MA zero point correction values previously determined by mapping and subsequently displayed on
the screen must be adopted for the performance of the measurement. However, the values previously
determined by means of "Measure machine zero point" will not be overwritten.
When mapping is performed the PASSPKT file (mapping file) of the station is created.
5.2.6 AXES INITIALIZING MENU
After selecting this main menu option a submenu appears (see Fig. 1.3) .
You can either initialize the X and Y-axis individually (e.g. to check the pulse generator of an axis) or initialize
all axes.
The "AXES INIT MENU" can also be called up from the "EDIT MENU".
5.2.7 DETERMINE CALIBRATION FACTORS OF HEAD CAMERA
This main menu option is used to determine the calibration factors of the head camera.
Calibration factors and camera offset (see next main menu option) are prerequisite for the execution of the
mapping menu (= glass mapping) options.
After determining the calibration factors, the camera offset must be determined.
5.2.8 DETERMINE CAMERA OFFSET and ADHESIVE NEEDLE OFFSET
This main menu option is used to determine the distance between PCB camera and adhesive nozzle and
subsequently the dispensing needle offset.
Prerequisite for this measuring routine is the determination of the calibration factors of the head camera.
Glass mapping cannot be performed until the camera and dispensing needle offsets have been determined.
5.2.9 CONVEYOR BELT WIDTH ADJUSTMENT
This function is designed to adjust, if required, the conveyor to the PCB width used.
The description of the menu option is contained in section 5.1.19!
On machines with automatic width adjustment, pay attention to the WORKAROUND section 12.2.
User’s Manual AutoCal Program 5 Description of the Menu Options
Software Version 114.xxx 5.2 Description of the Menu Options for HS-180 Adhesive Station II
5 - 15