EUKYX-199-2100_G5S2_Instruction_Vol2_E.pdf - 第134页
EUKYX 2-21 199-2100 3.3 Operation • 1 - Point Recognit ion Onl y the X and Y elemen ts are corre cted. The θ element (expans ion, etc.) i s not corrected. Fiducial Mark F2B16 • 2-Point Recognit ion Specify f iduc ial ma …

EUKYX
2-20199-2100
3.3 Operation
(C01_01)
PEC recognition function
Select one of the following options to determine whether or not this function should be used.
Disable : The PEC recognition function is not used.
Enable : The PEC recognition function is used.
When the PEC recognition function is not used in a pattern program, the program cannot be
used.
(C01_02)
All (Zones 1 through 5)
When the "PEC recognition function" is to be used, the setting for the global recognition is selected
from the following items for each zone.
Disable : The global recognition function is not activated.
1 Point : The global recognition function is implemented, using one fiducial mark.
2 Point : The global recognition function is implemented, using two fiducial marks.
3 Point : The global recognition function is implemented, using three fiducial marks.
(a) It is recommended that "2 Point" or more should be selected for the global recognition.
(b) By dividing the area for the PEC recognition into several zones, it became possible to
correct a local expansion of a large PCB, etc.
Notice
Note

EUKYX
2-21199-2100
3.3 Operation
• 1-Point Recognition
Only the X and Y elements are corrected. The
θ
element (expansion, etc.) is not corrected.
Fiducial Mark
F2B16
• 2-Point Recognition
Specify fiducial mark positions so that one fiducial mark is kept as diagonally away from the other
as possible.
Fiducial Mark
PCB
F2B17
Avoid making positional relation such as fiducial marks aligned vertically or horizontally with
each other as shown below.
F2B18
• 3-Point Recognition
Specify fiducial mark positions so that the triangle are formed by connecting the three points (three
fiducial marks) becomes as large as possible.
Fiducial Mark
F2B19
When any two of the three fiducial marks are designated to be positioned as close as possible
to each other, the results of the correction will be almost the same as "2-Point Recognition".
Note
Note

EUKYX
2-22199-2100
3.3 Operation
(C01_03)
Image
When "Enable" is selected, set one of the following options as an image recognition mode.
Disable : The image recognition function is not used.
Enable : The image recognition function is used.
Unit PCB (Multi-Unit PCB)
Fiducial Marks
F2B20
When the global recognition function is used together with the image recognition function,
both recognizing actions take place but the placement coordinates are corrected according to
the result of the image recognition.
(C01_04)
Local
Select one of the following options to determine whether or not the fiducial mark on each
component placement point should be recognized.
Disable : The local recognition function is not used.
Enable : The local recognition function is used.
(a) When "Enable" is set in the text box, the deviation of each component placement point
can be corrected.
(b) A component placement point and each recognition mode can be specified in "(D02_09)
V" of the placement data (P-data) and the coordinates and mark code of a fiducial mark
can be designated in (D02_12), (D02_13), and (D02_14) of the placement data (P-data).
(C01_05)
Zones 1, 2, 3, 4, and 5
When the PEC recognition mode is set with “All” function enabled, the coordinates and mark code
of each fiducial mark must be set.
1st Point X [mm] (Horizontal) and Y [mm] (Vertical)
Set the coordinates of the first fiducial mark in the text boxes.
1st Point Mark Code
Set the mark code of the first fiducial mark in this text box.
2nd Point X [mm] (Horizontal) and Y [mm] (Vertical)
Set the coordinates of the second fiducial mark in the text boxes.
2nd Point Mark Code
Set the mark code of the second fiducial mark in the text box.
3rd Point X [mm] (Horizontal) and Y [mm] (Vertical)
Set the coordinates of the third fiducial mark in the text boxes.
3rd Point Mark Code
Set the mark code of the third fiducial mark in the text box.
Refer to (C02) PEC Recognition Mark Data for the mark codes.
Note
Note
Reference