EUKYX 1-45 199-2100 [ 1 5 ] Pocket recog co ndition whe n restar ting The condi tions f or pocket recogn ition when the m ach ine operation i s re-s tared, are setup in t his s e c t io n. Function Setting "Enab le&…

EUKYX
1-44199-2100
[7] "Comp. size setting" Group Box
The allowance of the component pickup difference in above "[6] Comp. Recog. Detn" is set
in this text box.
Comp size 0603 and less
The component size smaller than that of 0603 component, is set in this text box.
0603 < Comp size <= 1005
The component size larger than that of 0603 component and smaller than that of 1005
component, is set in this text box.
Comp size 1608 and beyond
The component size larger than that of 1608 component, is set in this test box.
[8] Tape Joint Detection
One of the following buttons can be selected to determine whether or not an automatic
teaching operation should be performed on the feeder pocket recognition after a tape joint
line has been detected.
Disable
Select this button not to perform an automatic teaching operation on the feeder pocket
recognition after a tape joint line has been detected.
Enable
Select this button to perform an automatic teaching operation on the feeder pocket
recognition after a tape joint line has been detected.
[9] Recog Interval at Joint
When the operation is re-started, the interval time is set up in this data box in the case that
the feeder pocket recognition automatic teaching is performed periodically, based on the
tape feeding times.
[10] Pocket Recog Start Pos
The pocket recognition starting position is setup in this data box.
[11] Pocket Recog End Pos
The pocket recognition ending position is setup in this data box.
[12] Joint recog judge by comp recog
“Enable” or “Disable” is selected for the spliced tape joint detection function in this
selection box.
Disable
It is selected when the joint detection is not used.
Enable
It is selected when the joint detection is to be used.
[13] Joint tolerance
The joint allowance is setup in this data box, in the case of using the “Joint Recognition Judgment”
function.
[14] [ ]/[ ] Page change buttons
Changes the page of “Tape Pocket Recog“ window.
4.2 "Opr.Mode" Tab Sheet

EUKYX
1-45199-2100
[15] Pocket recog condition when restarting
The conditions for pocket recognition when the machine operation is re-stared, are setup in
this section.
Function Setting
"Enable" or "Disable" is selected for the pocket recognition condition in the re-start
operation, in this selection box.
Start condition
The time period from the machine stop (standby, stop or pause) mode to machine operation
start mode, is setup in this data box.
Recog Interval at Joint
The intervals for the automatic teaching to be performed periodically for the feeder pocket
recognition based on the number of tape feeding times when the machine operation is
re-started, are setup in this data box.
End condition (Interval)
The number of tape feeding times until the pocket recognition end, is setup in this data box.
4.2 "Opr.Mode" Tab Sheet

EUKYX
1-46199-2100
4.2.8 Splicing
When the [Splicing] button is pressed on the "Opr.Mode" tab sheet, the following window appears.
[3]
[2]
[1]
[4]
F2A35A
[1] Splicing tape length
The splicing tape length is set in this text box.
[2] "Stop Mode" Group Box
Splicing Stop (900 mm)
The [Enable] or the [Disable] button can be selected to determine whether or not the
machine should be stopped for tape splicing required when the length of the remaining tape
becomes shorter than 900 mm.
[3] “Warning Mode “ Group Box
The following conditions can be added to the criterion (Length of Remaining Tape: 900 mm) to set
the time to issue a warning of splicing need.
It cannot be specified to issue a splicing warning message with the length of the remaining
tape is shorter than 900 mm.
►
900 mm + Condition
The condition of displaying splicing warning is selected from the following items.
Tape Length
The condition for displaying the alarm for splicing, is set based on the remaining tape length.
PCB Count
The condition for displaying the alarm for splicing, is set based on the number of producible PCBs.
►
[Count] Button
When this button is pressed, it becomes possible to set the number of PCBs (PCBs that can be
produced) as a condition to issue a splicing warning message.
Note
4.2 "Opr.Mode" Tab Sheet