EUKYX-199-2100_G5S2_Instruction_Vol2_E.pdf - 第260页
EUKYX 6-23 199-2100 6.2 "Line" T ab Sheet 6.2 "Line " T ab Sheet Thi s tab sheet enables the operator to tra nsfer a PCB bet ween t wo or more mac hines. [1] Graphic Development F2F30 [ 1 ] Con vey or…

EUKYX
6-22199-2100
6.1 "Local" Tab Sheet
[5] [PCB Mem. Info.] Button
In the case that PCB presence/absence does not agree with the memory due to the removal of the
PCB, the PCB presence/absence data can be setup using the window operation.
F2F29
Light Blue : PCB Presence Status
Gray : PCB Absence Status

EUKYX
6-23199-2100
6.2 "Line" Tab Sheet
6.2 "Line" Tab Sheet
This tab sheet enables the operator to transfer a PCB between two or more machines.
[1]
Graphic
Development
F2F30
[1] Conveyor Image Display Section
Each block of the conveyor of which an image is displayed, functions as a button.
When the conveyor block button is pressed and within 10 seconds, the [START] button on the
operation panel is pressed, the PCB is transferred to the position.
(a) This button is displayed when two or more machines are installed in the line.
(b) Up to 16 conveyor blocks are displayed.
Note

EUKYX
6-24199-2100
6.3 "MNL XFER" Window
6.3 "MNL XFER" Window
This "MNL XFER" window enables the operator to transfer a PCB manually.
[2]
[2]
[4]
[3]
[1]
Graphic
Development
F2F31
[1] Conveyor Image Display Section
Each block of the conveyor, of which an image is displayed, functions as a button. When the
conveyor block button is pressed and within 10 seconds, the [START] button on the operation panel
is pressed, the PCB is transferred to the position.
[2] PCB LOCATE L and PCB LOCATE R
Using these buttons, PCB positioning is performed.
When the [Exec.] button is pressed and within 10 seconds the [START] button is pressed on the
operation panel, the PCB is positioned while the [START] button is being held down. When the
[Rlse.] button is pressed and within 10 seconds the [START] button is pressed on the operation
panel, the PCB positioning is released while the [START] button is being held down.
[3] [Stpr L] and [Stpr R]
Using these selection buttons, the stopper positioning is performed.
When the [UP] button is pressed and within 10 seconds the [START] button is pressed on the
operation panel, the selected backup base (stopper) is moved up while the [START] button is being
held down. When the [DOWN] button is pressed and within 10 seconds the [START] button is
pressed on the operation panel, the selected backup base (stopper) is moved down while the
[START] button is being held down.
[4] XFER Start
When the arrow button showing the direction to where the conveyor is to be moved, is pressed,
and within 10 seconds the [START] button is pressed on the operation panel, the conveyor is moved
while the [START] button is being held down.