EUKYX-199-2100_G5S2_Instruction_Vol2_E.pdf - 第272页
EUKYX 6-35 199-2100 7.2 "Place Pos T each" Window ► Automatic T eaching • Dat a to be Taught The fol lowi ng are da t a items to be taugh t. • PCB Pl acement Pos ition P 1 to Pn Step (X, Y) on Plac ement Da ta …

EUKYX
6-34199-2100
7.2 "Place Pos Teach" Window
7.2.3 Placement Position Teach Operation Procedure
The following describes the procedure based on the assumption that "Front Right" is selected
as placement coordinate references. "Pn" and "On" are taught as follows.
Unit Pattern Angle : 270°
Unit Pattern Angle : 0°
Pn
Pn
PCB Outermost Shape
Placement
Position
O
2
O1
Placement Position
Reference
Pattern Origin
Unit Control
Offset
PCB Origin
PCB Origin Offset
F2F40
Note

EUKYX
6-35199-2100
7.2 "Place Pos Teach" Window
►
Automatic Teaching
• Data to be Taught
The following are data items to be taught.
• PCB Placement Position P1 to Pn Step (X, Y) on Placement Data (P).
• Pattern Origin O1 to On Coordinates (X, Y) on the placement Data (O).
►
Notes on Teaching Operation
When the PEC recognition is set to ON on the pattern program data, all the PEC recognition
processing should be completed before the placement position check in the placement position
teach operation. If the PEC recognition has been set to ON, when the teaching is started while the
machine is stopped, the PEC recognition will be performed at first.
(1) Select the pattern program (production model) to be taught and prepare for PCBs, etc.
(2) Select the "Cycle run" in the "Place Pos Teach" window and set the movement speed.
(3) To find the overall shifting tendency of the PCB patterns, press the [START] button on the
operation panel within 10 seconds after pressing the [Cycle run] button.
(4) Select the component outline and the condition of the pattern displayed while the X/Y
beam is working and select the step to be taught.
When the patterns of a certain step are specifically shifted to one side, it is required to teach
the P-data. When the overall patterns of a unit PCB are uniformly shifted to one side, the
O-data must be taught.
(5) Press the [Back] button. (Return to the "Place Pos Teach" window.)
See “7.2 “Place Pos Teach” Window” for the button positions.
Procedure
Note
Reference

EUKYX
6-36199-2100
7.2 "Place Pos Teach" Window
►
Manual (Manual Axis Operation) Teaching
(1) Move to the teaching step with the following 3 procedures.
• [Cycle run] button
Press the [START] button on the operation panel within 10 seconds after pressing the [Cycle run]
button to start the automatic movement.
After the X/Y beam has moved to the object step for the teaching operation, stop the beam with the
[STOP] button on the operation panel.
• [Back Step] button, [Select Step] button, or [Next Step] button
Press the [START] button on the operation panel within 10 seconds after pressing the [Back Step]
button, [Select Step] button, or [Next Step] button. Repeat this until the X/Y beam moves to the
object step for the teaching operation.
• Selecting teaching step manually
Use the vertical scroll bar in the "Step Data" pane or select the object step for the teaching
operation with the [Dsig Step] button.
(2) Press the START button on the operation panel in 10 seconds after the [TEACH] button.
(3) Using the graphic image move buttons, match the component outer shape shown in the
recognition area with the PCB pattern captured in the recognition memory image, and
when the position is decided, press the [OK] button to determine the position.
(4) Press the [Return] button to display the “Place Pos Teach“ window. Check the new teach
result (X and Y) in “Teac Res“ cells.
(New placement position is registered temporarily and written in the file.)
(a) The Temp Entry function of the new placement position saves the temporary file for the
data for operation and pattern program file, but does not overwrite the data on the
original file.
(b) The temporarily entered step data can be cancelled. When it is to be cancelled, select
the step to be cancelled and press the [Cncl Dt] button.
(c) The temporarily entered step data is indicated with a “pale blue” background.
(d) The temporarily entered data is immediately reflected on the Auto Move and Step Move
operations.
(e) While the new placement position is being registered temporarily, it becomes impossible
to edit the current pattern program data.
(f) When all data items are to be cancelled, refer to (6).
Procedure
Note