EUKYX-199-2100_G5S2_Instruction_Vol2_E.pdf - 第200页

EUKYX 4-8 199-2100 2.1 "Mach.Prfrm," T ab Sheet [15] [15] [16] [17] F2D6 [ 1 5 ] Zone # 1 thr ough #5 1pt err (% of Total PEC Recog. err) Shown are the total n umber of errors detec ted on the f irst fiduc ial …

100%1 / 327
EUKYX
4-7199-2100
2.1 "Mach.Prfrm," Tab Sheet
[14]
F2D5
[14] Total components
Number of the pick-up operation times is displayed in this data box.
Total errs (A+B+C+G+L) (% of Total cmp)
Shown are the total number of pickup errors, the total number of components to be picked
up, and the percentage of picked components per total number of pickup errors.
A:comp.missing (% of Total err)
Shown are the number of component missing errors detected by the linear measure detection
sensor and the percentage of component missing errors per total number of pickup errors.
B:comp. missing (% of Total err)
Shown are the number of component missing errors detected in the recognition process and
the percentage of component missing errors per total number of pickup errors.
C:comp. vertical (% of Total err)
Shown are the number of vertical component errors detected by the linear measure detection
sensor and the percentage of vertical component errors per total number of pickup errors.
D:comp. recog (% of Total err)
Shown are the number of errors detected in the recognition process and the percentage of
errors per total number of pickup errors.
E:comp. thick (% of Total err)
Shown is the percentage of component thickness errors detected by the linear measure
detection sensor per total number of pickup errors.
F:pick-up difr. (% of Total err)
Shown are the number of pickup difference errors detected in the recognition process and
the percentage of the errors per total number of pickup errors.
G:comp. posture (% of Total err)
Shown are the number of reversed component and polarity judgment errors detected in the
recognition process and the percentage of the errors per total number of pickup errors.
H:measure. err (% of Total err)
The measurement value error count and percentage to the total error count are displayed in
this data box.
K:coplanarity (% of Total err)
The percentage of error detected in the optional device installation, is displayed in this data box.
L:obverse / reverse (% of Total err)
The percentage of the error times in the front/rear judgment using the linear measure to the
pick-up error total times, is displayed in this data box.
Total errors
Shown is the total number of component handling errors.
EUKYX
4-8199-2100
2.1 "Mach.Prfrm," Tab Sheet
[15]
[15]
[16]
[17]
F2D6
[15] Zone #1 through #5
1pt err (% of Total PEC Recog. err)
Shown are the total number of errors detected on the first fiducial mark and the percentage
of the detected errors per total number of all errors detected by the PEC recognition
function.
2pt err (% of Total PEC Recog. err)
Shown are the total number of errors detected on the second fiducial mark and the
percentage of the detected errors per total number of all errors detected by the PEC
recognition function.
3pt err (% of Total PEC Recog. err)
Shown are the total number of errors detected on the third fiducial mark and the percentage
of the detected errors per total number of all errors detected by the PEC recognition
function.
[16] Lcl fid.err (% of Total PEC recog. err)
Shown are the total number of recognition errors in each individual components and the percentage
of the detected errors per total number of all errors detected by the PEC recognition function.
[17] Total PEC recognition errors
Shown is the total number of errors detected by the PEC recognition function.
The number of errors detected by the global PEC recognition function and the total number of
errors detected by the BBR recognition function are displayed.
EUKYX
4-9199-2100
2.2 "FdrMng." Tab Sheet
2.2 "FdrMng." Tab Sheet
[1] [2] [3] [4] [6] [7] [8] [9]
[10] [11] [12] [13] [14] [15] [16] [17]
[18]
[5]
F2D8
(a) The displayed tab sheet will look different, depending on which option is selected.
(b) Each item box functions as a button and each pressing of the buttons can list the data
parameters in descending order. The top box shows the largest value for error times.
Therefore, it is useful for the analysis to enhance the operation rate. When the [Feeder
No.] button is pressed, the Nos. are re-arranged in their initial order (Feeder Nos.).
The "FdrMng." tab sheet is divided further into several tabs and each tab sheet shows the handling
errors per feeder on each individual feeder bases.
When each tab is pressed, the corresponding tab sheet appears.
Note