4.1 "Run Mode" Tab Sheet
Starting Procedure for Semi-Auto Step Any Desig (free designation)
(1) Transfer the PCB to the designated table.
Transfer the PCB manually to the aimed position.
(2) Designate the step in the "Any step designation" window and press the [Apply] button.
A dialogue "Do you save the change?" will be displayed. Select "Yes". After the selection, the
No. of designated steps is changed.
(3) Press the [Return] button to return to the "Semi-Auto Any Desig" window.
(4) When the [START] button on the operation panel is pressed, the designated step mounting
is started.
(a) Precautions during the step operation designated in “Any Step Designation” mode
• The addition or deletion of step operation designated in the “Any Step Designation”
mode, is disabled. Before or after the component placement, or after all applied steps
are cancelled in the case of stop in the course of the operation, such addition or deletion
is enabled.
• In the case that the step designated in “Any Step Designation” mode, is stopped in the
course of the operation and the placement is started again, the operation is started from
the head of the undone steps.
• In the case that the operation is to be started again, after the step designated in the “Any
Step Designation” mode, is stopped in the course of the operation and undone steps are
cleared, the operation is started from the head of the applied steps designated in “Any
Step Designation” mode.
• Even when the PCB is discharged after the operation is stopped in the course, the
operated step data is not cleared.
(b) After all the steps are performed
When the operation start is attempted after all the previously set steps are performed,
the component placement is not started. In order to start the component placement, clear
the previously set placement steps.
(c) Applied Steps Clearing Procedure
(1) Press the “Placement step clear” button on the “Semi-Auto Any Desig” window.
(2) Press the “Release all step” button on the “Any step designation” window and
press the “Apply” button.
(d) PCB Discharge
•
Discharge the PCB manually after all the steps designated in “Any Step Designation”
mode, are completed (including the stop in the course of the operation).
•
Start the normal operation after the PCB discharge.
Procedure
Note
Note
Note
Procedure

EUKYX
1-23199-2100
4.1 "Run Mode" Tab Sheet
4.1.2 "Run Mode" Window ("Warm Start" Possible)
When the machine is set in the "PAUSE" mode during the automatic operation, a warm start
operation becomes possible and the "Warm Start" window appears.
[1]
[2]
F2A21
[1] [Last Plc Pos Move] Button
When this button is pressed, the "Last Placement Point Check" window is opened.
[2] [Cancel Warm Start] Button
When pressed, the warm start is cancelled.
This button is displayed only in the window for the Supervisor. When the Warm start has been
stopped, the PCB is discharged without placing any component in the re-start operation. Pay
attention to it.
Refer to “5.3 Resumption of Production through Warm Start Procedure”
(Chapter 3 in Volume 1) for the detailed information on how to execute a warm start operation.
Note
Reference

EUKYX
1-24199-2100
4.1 "Run Mode" Tab Sheet
4.1.3 "Run Mode" Window in "Placement Recovery Available" Mode
"Enable" or "Disable" for the NL-axis Origin Teaching, is setup in this data box.
[1]
[2]
F2A22
[1] [Plc Pos Move] Button
When pressed, this button opens the "When the NL-axis origin teaching is to be performed, the
teaching time interval is selected from the following items." window.
A pre-pick nozzle confirmation error will not occur when the pre-pick nozzle confirmation
function is not used.
Refer to”4.2 “Opr.Mode” Tab Sheet” in "Chapter 1" for how to use the pre-pick nozzle
confirmation function.
When the machine is reset to its normal condition from the "ERROR" window after a pre-pick
nozzle confirmation error has occurred, the "Placement Step Recovery" window appears
automatically.
[2] [Cancel Place Rcvry] Button
When pressed, the placement recovery is cancelled.
Reference
Note