EUKYX-199-2100_G5S2_Instruction_Vol2_E.pdf - 第167页

EUKYX 2-54 199-2100 3.7 Placement (G03_03) Z=the ta [deg] Set angles f or component pl acement. The pla cement ang les must be d etermi ned accord in g to the packa ged posture of components on t he tape fee der . E xamp…

100%1 / 327
EUKYX
2-53199-2100
3.7 Placement
(G03) P-Data
When the [P-Data] button is pressed in the "Placement" window, the following tab sheet appears.
Graphic
Development
F2B49
(G03_01)
PNo
Shown are the step Nos. of the placement data (P).
Set coordinates and angles for component placement in the lines of the step Nos. (P-Nos.).
(G03_02)
X [mm] and Y [mm]
Set Coordinates X and Y for component placement. The coordinates must be based on the
placement coordinate reference (N0).
Y2
Y1
X1
X2
Y
X
Placement Coordinate Reference (No)
F2B50
EUKYX
2-54199-2100
3.7 Placement
(G03_03)
Z=theta [deg]
Set angles for component placement. The placement angles must be determined according to the
packaged posture of components on the tape feeder.
Example:
0 45 90 135 180 225 270 315
Front Side of Machine
Z=Theta
(Angle)
Feeder Bases #1
Packaged
Posture
User Direction
of Tape Feed
Packaged
Posture
User Direction
of Tape Feed
Feeder Bases #2
Rear Side of Machine
Packaged Posture of
Component on Feeder
Tape Feeder
PCB
Tape Feeder
0
90
180
270
F2B51
EUKYX
2-55199-2100
3.7 Placement
(G03_04)
H [mm]
The component placement height can be corrected.
H
Component
PCB
Reference Plane
F2B52
When a parameter is set as "H" data in the last line (last step No.), it becomes invalid because
"E" is set in the "C (Control Command)" text box.
(G03_05)
Component ID
Set component IDs in the text boxes.
(G03_06)
Fdr No.
Set the Nos. of the feeders loaded with components.
The feeder Nos. (Fdr Nos.) to be set here must be specified in the placement feeder location
data.
(G03_07)
Symbol
Use them to enter the characters written on the board, for wiring pattern, etc.
Max. 32 characters can be used to set.
Available characters are half-width alphabetical/numerical characters and symbols.
(a) The automatic operation is not affected by these comments.
(b) The comments can be used to check "Ref. No." printed on the upper surfaces of PCBs.
Note
Note
Note