EUKYX-199-2100_G5S2_Instruction_Vol2_E.pdf - 第219页
EUKYX 4-27 199-2100 4. "MESSAGE.RA TE.DT" Window 4. " M ESSA GE .R A TE .DT " W in dow 4. 1 " Feed er Me ssage Rat e " T ab Shee t Graphic Development F2D21 (a) The displayed tab sheet wil l…

EUKYX
4-26199-2100
3.3 "EdrMng." Tab Sheet
[14] F:Pick-up Diff
Each text box shows the total number of pickup difference errors detected in the recognition
process for each individual feeders.
[15] G:Comp. Posture
Each text box shows the total number of reversed component and polarity judgment errors detected
in the recognition process for each individual feeders.
[16] H:Meas. Error
Each text box shows the total count for each feeder where a measurement error has occurred.
[17] K:Copla. Error
Each text box shows the total number of coplanarity errors detected in each individual feeder.
[18] L:obv/Reverse
The "judged front/rear error" times for each feeder, detected using the linear measure, is displayed
in these data boxes.
[19] Shrtg. of Comp.
Each text box shows the total number of component shortage errors detected for each individual
feeders.
[20] Type
Each text box shows the type of the attached tape.
[21] Width
Each text box shows the tape feeder width.
[22] [All], [A Lane] and [B Lane] Buttons
Each text box shows the update date & time for each individual feeder.

EUKYX
4-27199-2100
4. "MESSAGE.RATE.DT" Window
4. "MESSAGE.RATE.DT" Window
4.1 "Feeder Message Rate" Tab Sheet
Graphic
Development
F2D21
(a) The displayed tab sheet will look different, depending on which option is selected.
(b) Each item box functions as a button and each pressing of the buttons can list the data
parameters in descending order. The top box shows the largest value for error times.
Therefore, it is useful for the analysis to enhance the operation rate. When the [Feeder
No.] button is pressed, the Nos. are re-arranged in their initial order (Feeder Nos.).
The window to display the feeder pickup information per feeder base is divided.
Pressing the [Fdr #1] or [Fdr #2] button displays the relevant feeder base window.
Note

EUKYX
4-28199-2100
4.1 "Feeder Message Rate" Tab Sheet
F2D22
[1] Feeder No. (Actual Fdr No.)
Shown are the feeder Nos.
[2] Component ID
Each text box shows the component IDs for each individual feeders.
[3] A:Comp. Missing
Each text box shows the total number of missing components detected by the linear measure
detection sensor for each individual feeders.
[4] B:Comp. Missing
Each text box shows the total number of missing components detected through recognition
operation for each individual feeders.
[5] C:Comp. Vertical
Each text box shows the total number of vertical component errors detected by the linear measure
detection sensor for each individual feeders.
[6] D:Comp. Recog
Each text box shows the total number of errors detected through recognition operation for each
individual feeders.