EUKYX-199-2100_G5S2_Instruction_Vol2_E.pdf - 第97页

EUKYX 1-47 199-2100 [ 4] "Fdr T ape J oint Dete ction" Group Box Fdr t ape jt det ect. Snsr "Enab le" or "Di sable" i s selected for the joi nt seam detec tion sensor . S et the joint Aut o.…

100%1 / 327
EUKYX
1-46199-2100
4.2.8 Splicing
When the [Splicing] button is pressed on the "Opr.Mode" tab sheet, the following window appears.
[3]
[2]
[1]
[4]
F2A35A
[1] Splicing tape length
The splicing tape length is set in this text box.
[2] "Stop Mode" Group Box
Splicing Stop (900 mm)
The [Enable] or the [Disable] button can be selected to determine whether or not the
machine should be stopped for tape splicing required when the length of the remaining tape
becomes shorter than 900 mm.
[3] “Warning Mode “ Group Box
The following conditions can be added to the criterion (Length of Remaining Tape: 900 mm) to set
the time to issue a warning of splicing need.
It cannot be specified to issue a splicing warning message with the length of the remaining
tape is shorter than 900 mm.
900 mm + Condition
The condition of displaying splicing warning is selected from the following items.
Tape Length
The condition for displaying the alarm for splicing, is set based on the remaining tape length.
PCB Count
The condition for displaying the alarm for splicing, is set based on the number of producible PCBs.
[Count] Button
When this button is pressed, it becomes possible to set the number of PCBs (PCBs that can be
produced) as a condition to issue a splicing warning message.
Note
4.2 "Opr.Mode" Tab Sheet
EUKYX
1-47199-2100
[4] "Fdr Tape Joint Detection" Group Box
Fdr tape jt detect. Snsr
"Enable" or "Disable" is selected for the joint seam detection sensor.
Set the joint Auto. Skip.
"Enable" or "Disable" is selected for the "Set the joint Auto. Skip".
Skip LG (Front)
The skip start position from the joint is set.
Skip LG (Rear)
The skip end position from the joint is set.
Fdr Tape Joint Detection ErrStop
When an error (E3) is caused in the tape feeder, the machine is stopped.
Refer to "SIGMA-G4/G5 Tape Feeder Instruction Manual" for the derails of the error codes for
the tape feeder.
Skip Func after comp missing det
"Enable" or "Disable" for the Skip after "No Component" detected is selected.
Tape Recog at handling error
“Enable” or “Disable” is selected for “Tape Recog at handling error”.
Reference
4.2 "Opr.Mode" Tab Sheet
EUKYX
1-48199-2100
4.2.9 Data
When the [Data] button is pressed on the "Opr. Mode" tab sheet, the following window appears.
[2]
[1]
F2A36A
[1] Temp Comp Lib Save Mode
One of the following options can be selected for saving the carrier data.
[Standard] Button
When selected, the data saving operation continues only when the component data is
perfectly consistent.
(Standard)
(Before Changeover)
101 AAA
102 BBB
103 CCC
104 DDD
(After Changeover)
All are initialized because
there is a difference in 102.
101 AAA
102 DDD
103 CCC
104 DDD
Initialized
Initialized
Initialized
Initialized
Simplified Packaging
Direction Change Function
F2A37
[Continuation 1] Button
The system keeps on saving only the component data that has the same ID.
(Continuation 1)
(Before Changeover)
101 AAA
102 BBB
103 CCC
104 DDD
(After Changeover)
The 102 data is initialized as
there is a difference.
The 104 data is cleared as
it is not used.
The other data are continued.
101 AAA
102 DDD
103 CCC
104
Continued
Initialized
Continued
Cleared
Simplified Packaging
Direction Change Function
F2A38
4.2 "Opr.Mode" Tab Sheet