EUKYX-199-2100_G5S2_Instruction_Vol2_E.pdf - 第204页

EUKYX 4-12 199-2100 2.3 "NozMng." T ab Sheet [ 1 ] Nozzl e No. Shown are the no z zle N os. [2] T ot al Comp Each te xt box shows the nu mber of pic kup actions f or each i ndivid ua l nozz les. [ 3] T ot al Hd…

100%1 / 327
EUKYX
4-11199-2100
2.3 "NozMng." Tab Sheet
2.3 "NozMng." Tab Sheet
The pickup information by head/nozzle is displayed.
When the [NozMng.] tab is pressed in the "MNG.DT." window, the following tab sheet appears
inside the window.
[1] [2] [3]
[4]
[6] [7]
[8] [9]
[10] [11] [12] [13] [14] [15] [16]
[17]
[5]
F2D10
(a) The displayed tab sheet will look different, depending on which option is selected.
(b) When one of the above buttons is pressed, the nozzle No. with the biggest parameter
under the selected button is displayed in the first line and nozzle Nos. having the
subsequent (second, third, fourth, ...) biggest parameters follow.
That is, parameters are re-arranged in order of error counts, making it easy to analyze
and improve production rate. When the [Noz.] button is pressed, the Nos. are
re-arranged in their initial order (Nozzle Nos.).
The “NozMng.” tab sheet is divided into windows displaying the operation information by nozzle
per head. The corresponding head window appears by pressing the button.
Note
EUKYX
4-12199-2100
2.3 "NozMng." Tab Sheet
[1] Nozzle No.
Shown are the nozzle Nos.
[2] Total Comp
Each text box shows the number of pickup actions for each individual nozzles.
[3] Total Hdlg Errors
The number of pick-up error total times is displayed in this data box.
[4] Rate of Hdlg Err (%)
The percentage of the pick-up error total times to the total pick-up times is displayed in this data
box.
[5] Total Errors
Each text box shows the total number of errors detected in [7] through [17].
[6] Rate of Error (%)
Each text box shows the percentage of the total number of errors per the number of picked
components.
[7] A:Comp. Missing
Each text box shows the number of missing components detected by the linear measure detection
sensor for each individual nozzles.
[8] B:Comp. Missing
Each text box shows the number of missing components detected through recognition operation for
each individual nozzles.
[9] C:Comp. Vertical
Each text box shows the number of vertical component errors detected by the linear measure
detection sensor for each individual nozzles.
[10] D:Comp. Recog
Each text box shows the number of errors detected through recognition operation for each
individual nozzles.
[11] E:Comp. Thick
Each text box shows the number of errors in component thickness detected by the linear measure
detection sensor for each individual nozzles.
[12] F:Pick-up Diff
Each text box shows the number of pickup difference errors detected in the recognition process for
each individual nozzles.
[13] G:Comp. Posture
Each text box shows the number of reversed component and polarity judgment errors detected in
the recognition process for each individual nozzles.
[14] H:Meas. Error
Each text box shows the total times of measured value error in each feeder.
[15] K:Copla. Error
Each text box shows the total times of detected “Coplanarity Error” in each feeder. This error is
detected in the option attachment.
[16] L:Obv / Reverse
The “judged front/rear error” for each nozzle, detected using the linear measure is displayed in this
data box.
[17] Nozzle Clear/Change Date
Each text box shows the clear date for each individual nozzles.
EUKYX
4-13199-2100
2.4 "Handling/Plac." Tab Sheet
2.4 "Handling/Plac." Tab Sheet
When the [Handling/Plac.] tab is pressed in the "MNG.DT." window, the following tab sheet
appears inside the window.
[1]
[2]
[3]
F2D12
[1] Z:Total components
Shown is the number of component picks.
*A:component missing[sensor]
Shown is the number of component missing errors detected by the component linear
measure detection sensor.
(Case: "NG" (No Good) in Component Recognition and Linear Measure Detection Sensor)
*B:component missing[recognition]
Shown is the number of component missing errors detected through component recognition
operation.
*C:component vertical[sensor]
Shown is the number of components judged "NG" (No Good) by the linear measure
detection sensor although they are judged "OK" through component recognition process.
*G:component posture[recognition]
Shown is the number of reversed component and polarity judgment errors detected in the
recognition process.
*L:obverse/reverse[sensor]
The "judged front/rear error" times for each feeder, detected using the linear measure, is
displayed in these data boxes.
*D:component recognition
Shown is the number of components judged “NG” (No Good) through recognition process.
*E:component thickness
Shown is the number of component thickness errors detected by the linear measure
detection sensor.
*F:pick-up difference
Shown is the number of components judged “NG” (No Good) through recognition process.
*H:measurement error
Shown is the number of measurement error.
*K:coplanarlty
Shown is the number judged error by coplanarity error detection.
This error is detected in the option attachment.