EUKYX-199-2100_G5S2_Instruction_Vol2_E.pdf - 第174页
EUKYX 2-61 199-2100 3.7 Placement (G 0 4 _07 ) B- X, B - Y [mm] When "Optional " is set in the "U ni t PCB" text box, it is requ ired to set t he coordi nat es of each un it PCB mark (each ba d mark) …

EUKYX
2-60199-2100
3.7 Placement
(G04_04)
H [mm]
The height for each individual patterns (unit PCBs) can be corrected.
When a parameter is set as "H" data in the last line (last step No.), it becomes invalid because
"E" is set in the "C (Control Command)" text box.
(G04_05)
C
Enter some of the following control commands.
If a control command other than the following ones is used, the step becomes invalid.
- (Hyphen) : This command handles the steps as those for component placement.
S : This command invalidates the steps specified as those for component placement.
C : This command invalidates the steps specified as those for component placement.
As for dispensers, these steps become valid.
D : This command handles the steps as those for component placement.
As for dispensers, these steps become invalid.
E : When placement data (O) is not created, this shows the end of the steps in the placement
data (P).
Confirm that "0" (zero) is set in the "X [mm]", "Y [mm]", and "Z=theta [deg]" text boxes of the
last line (last step No.) and set "E".
(G04_06)
Comment
Set a comment for each step No. Alphanumeric characters and symbols can be used. Up to 32
characters can be used.
The automatic operation is not affected by these comments.
Note
Note
Note
Note
Note
Note

EUKYX
2-61199-2100
3.7 Placement
(G04_07)
B-X, B-Y [mm]
When "Optional" is set in the "Unit PCB" text box, it is required to set the coordinates of each unit
PCB mark (each bad mark) based on the placement coordinate reference No. Unit: mm
Pattern 4 Pattern 3 Pattern 2 Pattern 1
(B-X
4, B-Y4) (B-X3, B-Y3) (B-X2, B-Y2) (B-X1, B-Y1)
Bad Mark of Pattern 4
Bad Mark of Pattern 3
Bad Mark of Pattern 2
Bad Mark of Pattern 1
Placement Coordinate
Reference (No.)
F2B57
(a) Do not set any coordinates in the text boxes of the last line (last step No.). Keep them as
"000.00".
(b) The function of bad board reject is optional.
Note

EUKYX
2-62199-2100
3.8 HDLG/PL
3.8 HDLG/PL
Graphic
Development
F2B58A
The "HDLG/PL" data is created automatically by means of the optimization processing.
Note