EUKYX-199-2100_G5S2_Instruction_Vol2_E.pdf - 第214页
EUKYX 4-22 199-2100 3.2 "Mach.Prfrm," T ab Sheet [16] [16] [17] [18] [19] F2D18 [ 1 6 ] Zones # 1 to #5 1pt err (% of Total PEC Recog. err) Shown are the total n umber of errors detec ted on the f irst fiduc ia…

EUKYX
4-21199-2100
3.2 "Mach.Prfrm," Tab Sheet
[15]
F2C17
[15] Total errs (A+B+C+G+L)/(% of Total cmp)
Shown are the total number of pickup errors, the total number of components to be picked
up, and the percentage of picked components per total number of pickup errors.
A:comp.missing (% of Total err)
Shown are the number of component missing errors detected by the linear measure detection
sensor and the percentage of component missing errors per total number of pickup errors.
B:comp. missing (% of Total err)
Shown are the number of component missing errors detected in the recognition process and
the percentage of component missing errors per total number of pickup errors.
C:comp. vertical (% of Total err)
Shown are the number of vertical component errors detected by the linear measure
detection sensor and the percentage of vertical component errors per total number of pickup
errors.
D:comp. recog (% of Total err)
Shown are the number of errors detected in the recognition process and the percentage of
errors per total number of pickup errors.
E:comp. thick (% of Total err)
Shown is the percentage of component thickness errors detected by the linear measure
detection sensor per total number of pickup errors.
F:pick-up difr. (% of Total err)
Shown are the number of pickup difference errors detected in the recognition process and
the percentage of the errors per total number of pickup errors.
G:comp. posture (% of Total err)
Shown are the number of reversed component and polarity judgment errors detected in the
recognition process and the percentage of the errors per total number of pickup errors.
H:measure. err (% of Total err)
Shown is the percentage of measurement error times based on the total error times.
K:coplanarity (% of Total err)
Shown is the error detected while the optional unit is attached.
L:obverse / reverse (% of Total err)
The percentage of the error times in the front/rear judgment using the linear measure to the
pick-up error total times, is displayed in this data box.
Total errors
Shown is the total number of component handling errors.

EUKYX
4-22199-2100
3.2 "Mach.Prfrm," Tab Sheet
[16]
[16]
[17]
[18]
[19]
F2D18
[16] Zones #1 to #5
1pt err (% of Total PEC Recog. err)
Shown are the total number of errors detected on the first fiducial mark and the percentage
of the detected errors per total number of all errors detected by the PEC recognition
function.
2pt err (% of Total PEC Recog. err)
Shown are the total number of errors detected on the second fiducial mark and the
percentage of the detected errors per total number of all errors detected by the PEC
recognition function.
3pt err (% of Total PEC Recog. err)
Shown are the total number of errors detected on the third fiducial mark and the percentage
of the detected errors per total number of all errors detected by the PEC recognition
function.

EUKYX
4-23199-2100
3.2 "Mach.Prfrm," Tab Sheet
[17] Lcl fid.err (% of Total PEC recog. err)
Shown are the total number of recognition errors in each unit PCB and the percentage of the
detected errors per total number of all errors detected by the PEC recognition function.
[18] Total PEC recognition errors
Shown is the total number of errors detected by the PEC recognition function.
The number of errors detected by the global PEC recognition function and the total number
of errors detected by the BBR recognition function are displayed.
[19] CPH (PCB transfer time included)
The placeable component quantity per hour including PCB transfer time.
Latest value:
The placeable component quantity per hour when the program pattern is produced at the
end.
Average value:
The placeable component average quantity per hour when the program pattern is being
produced.
Max value:
The placeable component maximum quantity per hour when the program pattern is being
produced.
CPH (Only placement time)
The placeable component quantity per hour excluding PCB transfer time.