EUKYX-199-2100_G5S2_Instruction_Vol2_E.pdf - 第326页

EUKYX 6-89 199-2100 8. "PCB.CNT ." Window • PCB Count er Sto p Procedur e ( 1 ) Display th e "PCB. CNT . " window . (2 ) Set t he "PCB Count er Stop M od e " to "Designat e" . (3 )…

100%1 / 327
EUKYX
6-88199-2100
8. "PCB.CNT." Window
8. "PCB.CNT." Window
This window enables the operator to set the number of PCBs to be produced.
[2]
[1]
Graphic
Development
F2F122
[1] PCB Counter Stop Mode
PCB Counter Stop Mode
[Designate] Button:
When this button is selected and the produced PCBs reach the value set in "Count" text box,
the PCB intake is stopped and after all the PCBs in the machine are discharged, the machine
is automatically stopped.
[No Designate] Button
When this button is selected, the PCB counter stop mode is not used.
Count
The number of produced PCBs for each lane for stopping the machine using the PCB Counter
Stop Mode, is set in this group box.
The set count is displayed in the "Count" data box in the "AUTO. OPN" window.
[2] [Init Value] Button
When this button is pressed, the set value for the "PCB Counter Stop Mode" is returned to the initial
value.
Note
EUKYX
6-89199-2100
8. "PCB.CNT." Window
PCB Counter Stop Procedure
(1) Display the "PCB.CNT." window.
(2) Set the "PCB Counter Stop Mode" to "Designate".
(3) Press the [Count] button to display the "Count" window and read the "Count" barcode in
the instruction sheet using the barcode reader attached to the machine. (The value read
with the barcode reader, will be displayed on the "Count" window).
F2F123
(4) Confirm the read value and when it is OK, press the [Set] button.
(5) Confirm that the read value has been entered in the "Count" data box.
When the value in the "Count" data box is re-set, press the [Count] button and change the set
value.
Procedure
Note
Surface Mounter
EUKYX-199-2100
Instruction Manual : Volume 2 September 2019