EUKYX-199-2100_G5S2_Instruction_Vol2_E.pdf - 第141页
EUKYX 2-28 199-2100 3.3 Operation (C03_03) Sequ ence Set one of the fol low in g options to speci fy t he tim in g of PEC recogni tion i mplementation . It is recommended t ha t " Af ter Pick -up" shou ld be se…

EUKYX
2-27199-2100
3.3 Operation
(C03) Operation Data
When the [Operation] button is pressed in the "Operation" window, the following window appears.
Graphic
Development
F2B23
(C03_01)
PEC recognition Set
Common : When selected, the PEC recognition is performed with the common setting to the
both lines.
Individual : When selected, the PEC recognition is performed with different setting for each
machine.
(C03_02)
Beam
It can be determined which beam should be used for the global and image PEC recognition
operations.
Beam 1 : Select this when only Beam 1 should be used for PEC recognition operations.
Beam 2 : Select this when only Beam 2 should be used for PEC recognition operations.
Automatic (1 or 2)
: The machine determines which beam (Beam 1 or 2) is more suitable for PEC
recognition operations and selects the better one.
Both Beam : Select this when both beams (Beams 1 and 2) should be used for PEC recognition
operations.
As for the local PEC recognition, the PEC recognition operations are performed with the beam
by which components are placed regardless of this designation of the PEC recognition beams.
Note

EUKYX
2-28199-2100
3.3 Operation
(C03_03)
Sequence
Set one of the following options to specify the timing of PEC recognition implementation. It is
recommended that "After Pick-up" should be set in normal cases.
The components must meet the following requirements.
When "After Pick-up" is selected, a component is picked up and the component recognition is
performed on the component while the PCB is being transferred to the PCB positioning section.
Since the component is already picked up, it can be placed soon after the PEC recognition
operation is performed, shortening the time to finish a PCB.
After Pick-up: The PEC recognition operation is performed after a component is picked up.
Before Pick-up: The PEC recognition operation is performed before a component is picked up.
This parameter should be selected when the PEC recognition operation cannot
be performed with a component being picked up.
Note

EUKYX
2-29199-2100
3.3 Operation
(C04) Set-up Data
Graphic
Development
F2B24
(C04_01)
Conveyor
Using these buttons, whether or not the conveyor width is setup in the pattern program change
operation, is set.