EUKYX-199-2100_G5S2_Instruction_Vol2_E.pdf - 第84页
EUKYX 1-34 199-2100 4.2 .4 Comp Handling When the [ Comp Handl ing] but ton is pressed on the "Op erati on Mode" t ab sheet, t he fol lowi ng t ab shee t ap pear s. [6] [1] [2] [3] [5] [4] F2A29B 4.2 "Opr.…

EUKYX
1-33199-2100
[8] Check Stop Fan
Displays the machine information when an error occurred in the cooling fan.
Disable
Machine information is not displayed even when detected the declining of the number of cooling
fan rotation. Note that the warning bar appears on the lower part of the screen when “Disable“ is
selected.
F2A28bB
Enable
Machine information is displayed when detected the declining of the number of cooling fan
rotation. "Check Stop Fan" function is activated.
4.2 "Opr.Mode" Tab Sheet

EUKYX
1-34199-2100
4.2.4 Comp Handling
When the [Comp Handling] button is pressed on the "Operation Mode" tab sheet, the following tab
sheet appears.
[6]
[1]
[2]
[3]
[5]
[4]
F2A29B
4.2 "Opr.Mode" Tab Sheet

EUKYX
1-35199-2100
[1] "Remaining comp on Nzl check after plcmnt" Group Box
This function is used to check if no foreign object or component adheres to the nozzle end before
the nozzle picks up a component.
When a foreign object or a component is detected, an "ERROR" window opens and the machine
stops running after it has taken an abandoning action.
►
Head 1, Head 2
Disable
When this button is selected, the pre-pick nozzle confirmation function is not activated.
Enable
When this button is selected, the pre-pick nozzle confirmation function is activated.
►
Borderline
This button makes it possible to determine the judgement level for the pre-pick nozzle confirmation
function.
Mode
Select the mode for Borderline from "Manual" or "Auto".
Data
Specify the set value for the Borderline when "Manual" is selected for Mode.
[2] "Comp Discard Mode" Group Box
Specify the timing to abandon the components.
►
Abandon Seq Sel
Aft Plcm
When this button is selected, the machine abandons the components that were left behind (not
placed) after it has placed the picked component on the PCB.
Bfr Plcm
When this button is selected, the machine abandons the components that cannot be placed before
it places the picked component on the PCB.
In normal cases, it is recommended that the [Bfr Plcm] button be selected. For the stage on
which the coplanarity unit (option) is installed, be sure to select the [Aft Plcm] button.
Blow Count
Specify the number of blowing times.
Blow time
Specify the period of time during which air should be blown.
Discard opn at comp missing
Select “Enable” or “Disable” for the component discarding movement when the component is
missing.
Notice
4.2 "Opr.Mode" Tab Sheet