EUKYX-199-2100_G5S2_Instruction_Vol2_E.pdf - 第150页
EUKYX 2-37 199-2100 3.4 Control (D02) PCB lo cate D ata When the [ PCB locate] t ab is pressed in the "Control" w indow , the fol lowi ng tab sheet appear s. Graphic Development F2B37 F2B38

EUKYX
2-36199-2100
3.4 Control
PCB Bottom [mm]
When PCBs with some components already mounted on the lower surfaces (back) by the input
machine are transferred to this machine, be sure to enter the thickness of the highest component in
the text box.
Tallest Previously Placed Component
PCB
Set this thickness in the text box.
F2B36
• Data Input Range: 0 to 30.000
(a) The set parameter is used to determine the position (elevation) of the first backup table
when the PCB is transferred to the PCB positioning section.
(b) When components are placed previously and the main machine is operated with "0.00"
(no previously placed components) in this text box, the support pins may interfere with
some of the previously placed components on the back of PCB while the PCB is being
transferred to the PCB positioning section.
(D01_04)
PEC expansion correction
"Enable" or "Disable" for the PEC Recognition Extension Correction, is selected in this selection box.
Note

EUKYX
2-37199-2100
3.4 Control
(D02) PCB locate Data
When the [PCB locate] tab is pressed in the "Control" window, the following tab sheet appears.
Graphic
Development
F2B37
F2B38

EUKYX
2-38199-2100
3.4 Control
(D02_01)
PCB detection off DLY
It is not currently used.
(D02_02)
PCB locate SET
Common : When selected, the PCB positioning is set commonly to the machines in the line.
Individual : When selected, the PCB positioning is set individually for each machine in the
line.
(D02_03)
PCB locate Sequence
The PCB positioning mode is set in this text box.
Standard : The positioning is performed with both backup base and Z clamp.
Change Z clamp timing : The positioning with Z clamp is performed
after completing the positioning with the backup base.
Vacuum support + Z clamp: The positioning is performed with the vacuum jig and Z clamp.
Only vacuum support : The positioning is performed with the vacuum jig only.
(D02_04)
UP
Positioning 1, Positioning 2
MOVE
The PCB moving up operation for positioning is selected from "Standard" or "Value Set".
Normally, "Standard" is selected.
Standard : When selected, the PCB is moved up for positioning based on the standard value
set in the machine.
Low Speed 1 : When selected, the operation speed is one step lower than the standard value.
Low Speed 2 : When selected, the operation speed is two step lower than the standard value.
Low Speed 3 : When selected, the operation speed is three step lower than the standard value.
Low Speed 4 : When selected, the operation speed is four step lower than the standard value.
Value Set : When selected, the speed value can be set freely.
1st speed DCLR SET
The backup base operation speed reduction rate is set in this text box.
This value is reflected on the first operation in the 2-stage operation in the PCB positioning, and
second operation in the 2-stage operation in the PCB releasing.
2nd speed DCLR SET
The backup base operation speed reduction rate is set in this text box.
This value is reflected on the second operation in the 2-stage operation in the PCB positioning, and
first operation in the 2-stage operation in the PCB releasing.
Z Clamp
Opr. waiting time: The Z-clamp operation WAIT time is set in this text box.
Opr. ST DLY timer: The time period from the backup base moving up start to Z-clamp moving up
start, is set in this text box
.