EUKYX-199-2100_G5S2_Instruction_Vol2_E.pdf - 第166页

EUKYX 2-53 199-2100 3.7 Placement (G0 3) P- Da t a When the [ P-Da ta] but ton is pressed in the "Pla cement" window , the fol lowin g tab sheet app ears. Graphic Development F2B49 (G03_0 1 ) PNo Shown are the …

100%1 / 327
EUKYX
2-52199-2100
3.7 Placement
(G02_04)
Recog Coord X1 [mm] and Recog Coord Y1 [mm]
Set the X1 and Y1 coordinates of the first fiducial mark based on the pattern origin.
Recog Coord X2 [mm] and Recog Coord Y2 [mm]
Set the X2 and Y2 coordinates of the second fiducial mark based on the pattern origin.
(G02_05)
Fiducial Mark FM1 and Fiducial Mark FM2
Set the mark Nos. of the first and second fiducial marks FM1 and FM2. Select the mark Nos. (Mark
Codes) specified in the PEC recognition mark data of the operation data.
(G02_06)
Unit PCB Recognition
One to three points are setup for the PEC recognition for each U data.
U02
U01
Global Recognition
Unit PCB Recognition
F2A48
EUKYX
2-53199-2100
3.7 Placement
(G03) P-Data
When the [P-Data] button is pressed in the "Placement" window, the following tab sheet appears.
Graphic
Development
F2B49
(G03_01)
PNo
Shown are the step Nos. of the placement data (P).
Set coordinates and angles for component placement in the lines of the step Nos. (P-Nos.).
(G03_02)
X [mm] and Y [mm]
Set Coordinates X and Y for component placement. The coordinates must be based on the
placement coordinate reference (N0).
Y2
Y1
X1
X2
Y
X
Placement Coordinate Reference (No)
F2B50
EUKYX
2-54199-2100
3.7 Placement
(G03_03)
Z=theta [deg]
Set angles for component placement. The placement angles must be determined according to the
packaged posture of components on the tape feeder.
Example:
0 45 90 135 180 225 270 315
Front Side of Machine
Z=Theta
(Angle)
Feeder Bases #1
Packaged
Posture
User Direction
of Tape Feed
Packaged
Posture
User Direction
of Tape Feed
Feeder Bases #2
Rear Side of Machine
Packaged Posture of
Component on Feeder
Tape Feeder
PCB
Tape Feeder
0
90
180
270
F2B51