7.3 "COMP RCG" Test Window
7.3.3 "Library Teaching New Creation" Tab Sheet
On this tab sheet, the initial data parameter entry is performed for the data to be created newly.
When the [Library Teaching New Creation] tab is pressed on the "COMP RCG" window, the
following tab sheet is displayed.
On this tab sheet, enter the parameters for "T" (Thickness), "t" (Thickness) and "Ut" (Thickness).
If this setting is not performed, the procedure does not go to the next step.
Refer to ”Volume 6 : Component Library” for the description of each item.
[1]
[2]
[4]
[5]
[6]
[3]
Graphic
Development
F2F47
[1] [Comp ID] Button
In this data box, enter the component ID to be created.
Enter the component ID. If this setting is not performed, the procedure does not go to the next
step.
[2] [Comment] Button
The comment for the component can be entered in this text box.
[3] Input Data Change Button
[Shape Data]:
The shape data entry window is displayed.
[Control Data]:
The control data entry window is displayed.
[Carrier Data]:
The carrier data entry window is displayed.
[4] [Fr.] Button
When this button is pressed, the component recognition test window for the Test & Teaching
operation is transferred.
Refer to “7.3.4 “Component Recognition Test ExecutionWindow” for the “COMP RCG
window for the Test & Teaching operation.
[5] [Return] Button:
When this button is pressed, the “COMP RCG” test window is returned.
[6] Shape Data Entry Window:
In this window, enter the shape data.
Note
Reference
Note
Reference
EUKYX
6-43199-2100
7.3 "COMP RCG" Test Window
[7] Control Data Entry Window (1/4)
Enter the parameter for the “Nozzle ID”. If this setting is not performed, the procedure does not
go to the next step.
[7]
[7]
[7]
[7]
Control Data (1/4 page)
Control Data (2/4 page)
Control Data (3/4 page)
Control Data (4/4 page)
F2F48
[8] Carrier Data Entry Window:
In this window, the carrier data parameters are set.
[8]
F2F52
Note
EUKYX
6-44199-2100
7.3 "COMP RCG" Test Window
7.3.4 "Component Recognition Test Execution" Window
When the test ID is selected on the "COMP RCG" test window and the [Fr.] button is pressed, the
component recognition test execution window appears.
[1] [9]
[4]
[5]
[6] [7] [8]
[2]
[3]
Graphic
Development
F2F53
[1] Test ID
The text ID selected in the "COMP RCG" test window is displayed in this pane.
Nozzle ID
The nozzle ID (type) specified in the test ID is displayed in this pane.
[2] Displayed Image Operation Buttons
Using the following buttons, the mode is changed to perform the enlargement or movement
operation of the image displayed in the recognized image display pane [3].
[
] Button : Normal Operation Mode
[
] button : Image Enlargement Mode
After changing to the image enlargement mode using the [
] button (the shape of the pointer is
changed to
), when the image to be enlarged is touched, or the left button of the mouse is
clicked on the image, the image is enlarged from the pointer position as the center.
When the image is to be enlarged with its position fixed, place the pointer on the center of the
image before the enlargement operation.