3 Technical data User manual SIPLACE X-Series 3.8 Electrical and pneumat ic connection points S oftware Version SR. 601.xx 11/2005 US Edition 142 3.8 Electrical and pneum a tic connection point s 3.8.1 Electrical connect…

100%1 / 464
User manual SIPLACE X-Series 3 Technical data
Software Version SR.601.xx 11/2005 US Edition 3.7 Placement heads
141
3.7.5.3 Technical data
*) Please note that the component range that can be placed is also affected by the pad geometry, the customer-specific
standards and the packaging tolerances.
**) If standard nozzles are used
Optical centering with Stationary P&P component camera
(type 33) 55 x 45, digital
Stationary P&P component camera
(type 25) 16 x 16, digital
Component range *) 0603 to SO, PLCC, QFP, BGA, spe-
cial components, bare dies, flip-chips
0201 to SO, PLCC, QFP, sockets,
plugs, BGA, special components,
bare dies, flip-chips, shields
Component specification
Max. height
Min. lead pitch
Min. ball pitch
Min. ball diameter
Min. dimensions
Max. dimensions
Max. weight
25 mm (higher available on request)
0.3 mm
0.45 mm
0.25 mm
0.5 x 0.5 mm²
55 x 45 mm² (single measurement)
For use with two nozzles
50 x 50 mm² or
69 x 10 m
For use with one nozzle:
85 x 85 mm² or
125 x 10 mm²
up to 200 x 125 mm² (with restrictions)
100 g **)
25 mm (higher available on
request)
0.25 mm
0.14 mm
0.08 mm
0.2 x 0.2 mm²
16 x 16 mm² (single measurement)
100 g **)
Programmable set-down
force
1.0 N - 15 N 1.0 N - 15 N
Nozzle types 5 xx (standard)
4 xx + adapter
8 xx + adapter
9 xx + adapter
5 xx (standard)
4 xx + adapter
8 xx + adapter
9 xx + adapter
Nozzle spacing on the
two Pick&Place heads
70.8 mm 70.8 mm
X/Y accuracy ± 26 µm / 3 σ, ± 35 µm / 4 σ ± 22 µm / 3 σ, ± 30 µm / 4 σ
Angular accuracy ± 0.05° / 3 σ, ± 0.07° / 4 σ ± 0.05° / 3 σ, ± 0.07° / 4 σ
3 Technical data User manual SIPLACE X-Series
3.8 Electrical and pneumatic connection points Software Version SR.601.xx 11/2005 US Edition
142
3.8 Electrical and pneumatic connection points
3.8.1 Electrical connection points
3
Fig. 3.8 - 1 Electrical connection points on the placement machine
(1) Main power switch
(2) Cover over the power supply unit
(3) Power supply unit
(4) Angle for the cable gland
(5) Power cable
(T) Direction of PCB transport
User manual SIPLACE X-Series 3 Technical data
Software Version SR.601.xx 11/2005 US Edition 3.8 Electrical and pneumatic connection points
143
3.8.2 Pneumatic connection point
Fig. 3.8 - 2 Pneumatic connection point on the placement machine
3
(1) Pneumatic unit
(2) Coupling for connecting the compressed air hose
(3) Stop valve
(4) Recess for the air hose
WARNING
NEVER detach compressed air lines while they are still pressurized. Risk of injury. 3