4 Setting up and commissioning User manual SIPLACE X-Series 4.4 Setting up the placement machine Software Version SR.601.xx 11/2005 US E dition 206 4.4.7.5 F itting the g rounding cable for t he doors Æ Fix the two groun…

100%1 / 464
User manual SIPLACE X-Series 4 Setting up and commissioning
Software Version SR.601.xx 11/2005 US Edition 4.4 Setting up the placement machine
205
Æ Introduce the mandrel (item 5 in Fig. 4.4 - 9) of the conveyor cover into the hole (item 6 in Fig.
4.4 - 9
) in the second half of the extension kit.
Æ Position the second half of the extension kit so that the assembly bracket lies on the assembly
bar (item 7 in Fig. 4.4 - 8
).
Æ Fix the second half of the machine using 2 fillister head screws M6x16 and washers (item 3
in Fig. 4.4 - 8
).
4.4.7.3 Fixing the hexagonal shaft guide
Æ On the single conveyor, fix
one
guide for the hexagonal shaft (item 8 in Fig. 4.4 - 7) to the
extension kit using two fillister head screws M6x16 and washers.
Æ On the double conveyor, fix two guides for the hexagonal shaft (item 8 in Fig. 4.4 - 7) to the
extension kit using two fillister head screws M6x16 and washers.
4.4.7.4 Connecting the power cables - Extension kit on the PCB output side
4
4
4
4
4
Left-hand side of the extension kit
(viewed in the direction of travel)
Connector/cable To connector/cable
Emergency stop button
Start/Stop button
X63/03020687 X63/03002526
Protective cover switch, location 3
X53/03020409 X53/03002528
Button for the component trolley docking unit,
location 3
X232/03021056 X232/03021053
Right-hand side of the extension kit
(viewed in the direction of travel)
Connector/cable To connector/cable
Start/Stop button
Switch, PCB conveyor cover
X62/03020410 X62/03002525
Protective cover switch, location 2
X52/03006476 X52/03002527
Button for the component trolley docking unit,
location 2
X222/03021056 X222/03021052
4 Setting up and commissioning User manual SIPLACE X-Series
4.4 Setting up the placement machine Software Version SR.601.xx 11/2005 US Edition
206
4.4.7.5 Fitting the grounding cable for the doors
Æ Fix the two grounding cables for the doors (item 4 in Fig. 4.4 - 8) to the machine frame as
follows:
4
Fig. 4.4 - 10 Fitting the grounding cable
4
4
4
4
4
4.4.7.6 Checking and setting the protective cover switch
Æ Check that the protective cover switch (item 7 in Fig. 4.4 - 9, page 204) is working correctly.
Æ Adjust the protective cover switch if necessary (see Service Manual).
Hex nut M5
Spring washer M5, DIN 7980
Washer M5, DIN 125
Cable lug, annular
Contact washer
User manual SIPLACE X-Series 4 Setting up and commissioning
Software Version SR.601.xx 11/2005 US Edition 4.4 Setting up the placement machine
207
4.4.7.7 Installing the "bottom" hand guard
The machines from the X-series are supplied with just
one
"bottom" hand guard. If the machines
are installed within a line, then no hand guard is required between immediately adjacent output
and input conveyors.
WARNING 4
Always fit the "bottom" hand guard (item no. 03003432-01) on the input side of the
first
place-
ment machine and on the output side of the
last
placement machine of a line using 4 hexagon
socket head screws M4x12. This will prevent your personnel reaching into the machine without
authorization.
4
Fig. 4.4 - 11 Fitting the "bottom" hand guard on the PCB output side
(1) "Bottom" hand guard, item no. 03003432-01