X3_X4_Series machine.pdf - 第362页

6 Component handling User manual SIPLACE X-Series 6.9 Used tape c hannel - component t rolley docking unit SIPLAC E HF Software Version S R.601.xx 11/2005 US Edition 362 6.9 Used t ape channel - component trolley dock in…

100%1 / 464
User manual SIPLACE X-Series 6 Component handling
Software Version SR.601.xx 11/2005 US Edition 6.8 Used tape chute, SIPLACE HF
361
6.8 Used tape chute, SIPLACE HF
6
Fig. 6.8 - 1 Used tape chute for SIPLACE HF
PLEASE NOTE 6
The SIPLACE HF used tape chute can only be installed on the SIPLACE HF component trolley
docking unit (see Fig. 5.10 - 6, page 281.
6 Component handling User manual SIPLACE X-Series
6.9 Used tape channel - component trolley docking unit SIPLACE HF Software Version SR.601.xx 11/2005 US Edition
362
6.9 Used tape channel - component trolley docking
unit SIPLACE HF
6.9.1 Separating plate for tape pocket heights up to 17 mm
In the standard version, the used tape channel can guide component tapes with a maximum
pocket height of 17 mm to the pneumatic tape cutter.
6
Fig. 6.9 - 1 Used tape channel, SIPLACE HF
(1) Inlet slot for the used tapes
(2) Outlet slot for the used tape above the pneumatic tape cutter
(3) Dividing plate for tapes < 17 mm (can be removed for tapes > 17 mm)
(4) DIN 84 - M3x6 screw, 2x
User manual SIPLACE X-Series 6 Component handling
Software Version SR.601.xx 11/2005 US Edition 6.9 Used tape channel - component trolley docking unit SIPLACE HF
363
6.9.2 Removing the separating plate for tape pocket heights > 17 mm
If S feeder modules that process component tapes with a pocket height > 17 mm are used, such
as, for example, the 44 mm S DP feeder module, then the separating plate (item 3 in Fig. 6.9 - 1
)
must be removed.
WARNING 6
Æ Switch the placement machine off at the main switch to remove the dividing plate.
Æ Disconnect the machine from the power and compressed air supply.
Æ Secure the machine to prevent it being switched on again, as described in section 2.10, page
86
.
Æ Wait until the operating pressure for the tape cutter has dropped to 0 MPa.
Æ Wear robust protective gloves.
Æ Do not reach inside the used tape channel.
Æ Loosen the two slotted screws (item 4 in Fig. 6.9 - 1).
Æ Pull out the dividing plate.
PLEASE NOTE
Do not position feeder modules with shallow pockets immediately beside bar feeder modules
with deep pockets. The used tapes could overlap and build up.