User manual SIPLACE X-Series 2 Operational safety
Software Version SR.601.xx 11/2005 US Edition 2.9 Energy state of the machine after switching off at the main power switch
81
2
Fig. 2.9 - 3 Position of the computer unit
(1) Computer unit (top part)
(2) Power supply unit ± 12 V- 15 V-
(3) Power supply unit + 5 V-/+ 52 V-
(4) Power supply unit + 3.3 VDC
(T) Direction of PCB transport
2 Operational safety User manual SIPLACE X-Series
2.9 Energy state of the machine after switching off at the main power switch Software Version SR.601.xx 11/2005 US Edition
82
2.9.1 Placement system switched off at the main switch, but still connected ...
WARNING
The following components still carry potentially lethal voltages even if the main power switch is
switched off:
Cable connecting terminals L1, L2, and L3 in the main power switch Q1 (see Fig. 2.9 - 4
)
Service socket X102 (see Fig. 2.9 - 4
)
Automatic circuit breaker F1 for the service socket (see Fig. 2.9 - 4
)
Mains filter Z1 (see Fig. 2.9 - 5
)
L20 discharge reactor with fuses F21, F22, and F23 (see Fig. 2.9 - 5
)
Terminal block X100 for connecting the power supply cable (see Fig. 2.9 - 5
)
The color of all individual wires, which still carry potentially lethal voltages even if the main
power switch is switched off, is brown.
–Axis unit
User manual SIPLACE X-Series 2 Operational safety
Software Version SR.601.xx 11/2005 US Edition 2.9 Energy state of the machine after switching off at the main power switch
83
2
Fig. 2.9 - 4 Power supply unit, front view
Q1 Main power switch
X102 Service socket
F1 Fuse for the service socket