2 Operational safety User manual SIPLACE X-Series
2.6 Safety equipment Software Version SR.601.xx 11/2005 US Edition
66
2.6.2.3 Description of the functions
Main power switch in the OFF position (see item 1 in Fig.
2.6 - 3) 2
The main power switch disconnects the three phases L1, L2, and L3 from the power supply.
WARNING
The following components still carry potentially lethal voltages even if the main power switch is
switched off:
– Cable connection terminals L1, L2, and L3 of the Q1 main power switch
– Z1 line filter
– Service socket X102
– F1 automatic circuit breaker for the service socket
– The color of all individual wires, which still carry potentially lethal voltages even if the main
power switch is switched off, is brown.
Æ Death, serious injury or considerable damage may result if these automatic placement sys-
tems are handled incorrectly.
Æ Always follow the applicable accident prevention and DIN regulations (particularly DIN EN 60
204, part 1) and the applicable regulations in your own country.
Æ The safety door to the power supply must ONLY be opened by appropriately qualified and
trained personnel.
Main power switch in the ON position 2
After switching on the main power switch, the station computer and the machine controller will
start. All supply voltages, apart from the link voltages for the gantry axes (250 VDC) and the star
axes (145 VDC) are then available.
Stop button, black (items 2 and 7 in Fig. 2.6 - 3 and items 3 and 5 in Fig. 2.6 - 4) 2
These buttons are used to stop the placement system.
Start button, white (items 3 and 6 in Fig. 2.6 - 3 and items 2 and 4 in Fig. 2.6 - 4) 2
After switching on the main power switch you will be prompted to press the Start button in order
to start the placement system for placement jobs. The same prompt appears if you open the pro-
tective covers or the press the emergency stop button.

User manual SIPLACE X-Series 2 Operational safety
Software Version SR.601.xx 11/2005 US Edition 2.6 Safety equipment
67
Component counter (item 4 in Fig. 2.6 - 3) 2
This displays the number of inserted components.
Emergency stop button, latching, with override protection to EN 418
(item 5 in Fig.
2.6 - 3 and item 1 in Fig. 2.6 - 4) 2
The emergency stop button is red and latches in the ON position when pressed. When you press
the emergency stop button the switching contact of the emergency stop circuit opens and the pro-
tective contactor combination (PCC K6) trips. The link voltage (250 VDC) for the gantry axes and
the link voltage (145 VDC) for the star axes is switched off. The servo amplifiers for the DP and Z
axes are still supplied with 40 VDC. The signaling contact of the emergency stop button opens
and the message "emergency stop pressed" appears on the screen. The following modules are
deactivated:
– PCB conveyor
– PCB clamping
– width adjustment
– PCB stopper and the
– used tape cutter
PLEASE NOTE
Placement is interrupted and can then either be continued or canceled once the machine is work-
ing correctly again. 2
Button for docking the component trolley in or out 2
There are two buttons on the input and output sides of the machine for docking the component
trolley in or out.
– Button (Pos. 6 in Fig. 2.6 - 4
) for docking the component trolley in or out at location 1
– Button (Pos. 8 in Fig. 2.6 - 3
) for docking the component trolley in or out at location 2
– Button (Pos. 9 in Fig. 2.6 - 3
) for docking the component trolley in or out at location 3
– Button (Pos. 7 in Fig. 2.6 - 4
) for docking the component trolley in or out at location 4
The component trolleys can only be docked in if the protective covers are closed.
Protective cover switches 1, 2, 3 and 4 (item 1, 2, 3 and 4 in Fig. 2.6 - 5) and protective switch
for the cover flaps on the PCB conveyor input and output side (items 5 and 6 in Fig.
2.6 - 5) 2
These switches check whether the protective covers and the cover flaps are closed. When they
are closed, the emergency stop contact and the signaling contact are closed. If one of the covers
or the cover flaps is opened, the emergency stop contact and the signaling contact open. Some
components are deactivated or remain active (see Fig. 2.6 - 8
, page 72).

2 Operational safety User manual SIPLACE X-Series
2.6 Safety equipment Software Version SR.601.xx 11/2005 US Edition
68
2.6.3 Position of protective contactor combination and service socket
2
Fig. 2.6 - 6 Position of protective contactor combination and service socket
2
(1) Protective contactor combination
(2) Service socket