X3_X4_Series machine.pdf - 第146页

3 Technical data User manual SIPLACE X-Series 3.9 Controls Software Version S R.601.xx 11/2005 US Edition 146 Component barcode scanner 3 On each sid e of the middle co nsole there is a bracket that holds the Datalogic D…

100%1 / 464
User manual SIPLACE X-Series 3 Technical data
Software Version SR.601.xx 11/2005 US Edition 3.9 Controls
145
3.9.2 Description
All the controls can be reached by a 1.60 m tall person.
Main power switch 3
The main power switch is used to switch the power supply to the placement machine on and off.
WARNING
Some parts inside the placement machine carry potentially lethal voltages - even when switched
off at the main power switch. 3
Stop button 3
This button is used to stop the placement machine.
Start button 3
This button starts the placement machine after it has been switched on or after faults have been
eliminated.
Emergency stop button 3
The emergency stop button latches in the ON position when pressed. The power supply to the
gantry axes, the component trolleys, conveyors and used tape cutters is interrupted and the volt-
age supplied to the star axes of the placement heads is reduced. Turn the button to release it.
Component counter 3
The component counter displays the number of components processed in increments of ten.
LCD touchscreen 3
There is a flat LCD screen with a touch-sensitive surface (touchscreen) on either side of the place-
ment machine.
Keyboard 3
The keyboard is located beneath the monitor.
Indicator lamps 3
The sequence of colors of the indicator lamps is white - green. These lamps are used to signal
operating statuses and malfunctions of the placement machine.
3 Technical data User manual SIPLACE X-Series
3.9 Controls Software Version SR.601.xx 11/2005 US Edition
146
Component barcode scanner 3
On each side of the middle console there is a bracket that holds the Datalogic DL 910 component
barcode scanner. The barcode scanner enables the components to be set up and topped up
quickly and reliably.
3.9.3 Ergonomic arrangement of the controls
Figure 3.9 - 1 on page 144 provides an overview of the position of the controls. They are subdi-
vided into the following groups:
Operator panel on the right-hand side (pneumatic unit) of the center console with 3
LCD touchscreen
Keyboard with trackball
Start button, Stop button
Operator panel on the left-hand side (power supply unit) of the center console with 3
LCD touchscreen
Keyboard with trackball
Component counter
Start button
Stop button
Main power switch
Input / output side of the PCB conveyor with 3
Emergency stop button
Start button, Stop button
Button for docking and undocking the component trolley
User manual SIPLACE X-Series 3 Technical data
Software Version SR.601.xx 11/2005 US Edition 3.9 Controls
147
3.9.3.1 Controls on the placement machine's operator panels
The two operator panel have identical control functions.
Monitor, keyboard, Start and Stop buttons 3
There is a monitor and a keyboard on both sides of the placement machine.
The Start and Stop buttons are located beneath the keyboard. The on-screen dialog will occasion-
ally prompt you to activate certain actions using buttons, and this arrangement will make it easier
for you both to activate and to interactively control these actions.
Main power switch 3
The main power switch is part of the power module. It is located on the left-hand operator panel
viewed in the direction of PCB transport. It is located here because it is only needed for servicing
and preventive maintenance work and is therefore not subject to frequent use.
3.9.3.2 Controls on the input and output sides of the placement machine
The controls on the input and output sides of the placement machine perform identical functions.
Emergency stop buttons, Start and Stop buttons 3
There is an emergency stop button and Start and Stop buttons on both the input and output sides
of the PCB conveyor. This arrangement was adopted for the buttons because it enables them to
be reached quickly and easily from any position.
In addition, it is important to have an unrestricted view of the placement heads and placement area
during preventive maintenance, servicing and setting up work in order to be able to check all the
operations carried out inside the machine. This particularly important during testing phases or
when starting single functions, for example.