• Do not expose the machine to combustible or corrosive gas. Fig. 1X30 • Select a place free of lamp soot and dust. Fig. 1X31 • Level the machine at the correct height, using a level vial. Fig. 1X32 • The machine should …

100%1 / 145
Ambient temperature must be 20±10°C and humidity 30 to 80%. Any dew condensation
must be avoided.
When the machine is transferred to another place and the ambient temperature rises
more than the surface of the machine, dew may condense under the condition described
below.
Note that dew condensation may cause the machine to break down.
Condition of Dew Condensation
Dew may condense when the difference (based on "Humidity (%)") between the ambient
temperature of the destination (the place where the machine was transferred) and the
surface temperature of the machine reach the values or more in the table below.
Humidity (%) of Destination Differences between Ambient Temperature of
Destination and Surface Temperature of Machine
80 3°C or more
70 6°C or more
60 8°C or more
50 10°C or more
40 14°C or more
30 18°C or more
Fig. 1X28
Ensure that the selected place is free of electric noise.
Precautionary measures (prevention of noise generation, etc.) must be taken for other equip-
ment to prevent malfunctions.
Fig. 1X29
2.6 Pre-Installation Checks
0207-004 23 AFO01EOPP
Do not expose the machine to combustible or corrosive gas.
Fig. 1X30
Select a place free of lamp soot and dust.
Fig. 1X31
Level the machine at the correct height, using a level vial.
Fig. 1X32
The machine should be free of obstacles around it for easy maintenance.
Fig. 1X33
2.6 Pre-Installation Checks
0207-004 24 AFO01EOPP
Primary power supply must be connected to Terminals "L1", "L2", and "L3" and the ground
wire to "PE".
Voltage : 200±20 V AC, 3-Phase
Apparent Power : TCM-X100: Approx. 16 kVA
TCM-X200: Approx. 16 kVA
TCM-X300: Approx. 16 kVA
Note: Make the PE wire longer than the others "L1 through L3 wires", giving some leeway.
Fig. 1X34
Clean, dry, and non-lubricated air (air containing no moisture, oil, and dust) must be supplied
at an air pressure of 0.45 to 0.69 MPa (4.6 to 7 kgf/cm
2
).
Fig. 1X35
2.6 Pre-Installation Checks