1OM-1050-002.pdf - 第45页
4.1 Safety Switches Switch Name Countermeasures 4.1.2 [Front Safety Door Check] Switch When the front safety door is opened with the [OPERA TION] switch set to "RUN", the switch is activated and an error occurs…

4. Safety-Related Functions
4. Safety-Related Functions
This session describes the safety switches and module protection sen-
sors.
4.1 Safety Switches
When an error is detected in the machine, the safety switches are de-
signed to stop the dangerous moving mechanisms of the machine. Ev-
erything is processed on the machine side (hardware) without using
any software application on the computer side.
4.1.1 [EMERGENCY STOP] Switches
Press one of the [EMERGENCY STOP] switches to immediately stop
the machine in an emergency. The power is turned off and the machine
stops immediately.
Fig. 1X51-1 [EMERGENCY STOP] Switch
0301-005 42 AFO01EOPP

4.1 Safety Switches
Switch Name Countermeasures
4.1.2 [Front Safety Door Check] Switch
When the front safety door is opened with the [OPERATION] switch set
to "RUN", the switch is activated and an error occurs.
When the switch is set to "SETUP", it is not activated.
Table 1X7
Switch Name Countermeasures
Table 1X6
[EMERGENCY STOP] Switch (1)
[EMERGENCY STOP] Switch (2)
[EMERGENCY STOP] Switch (3)
[EMERGENCY STOP] Switch (4)
Pressing one of the [EMERGENCY STOP]
switches cuts power to the following modules.
• All power sources for loads are shut off.
The power supply to the mechanisms of all mo-
tor shafts and 24-voltage loads in the solenoid
system (SOL and SV) is shut off.
Note: The load power supply for the vacuum
pump and the DD motor is excluded. The
control power supply for the control boards
and sensors is also excluded.
When the front safety door is opened, the following
measures are taken.
• All power sources for loads are shut off.
The power supply to the mechanisms of all mo-
tor shafts and 24-voltage loads in the solenoid
system (SOL and SV) is shut off.
Note: The load power supply for the vacuum
pump and the DD motor is excluded.
The control power supply for the control
boards and sensors is also excluded.
[Front Safety Door Check] Switch
0301-006 43 AFO01EOPP

4.1.3 [Feeder Work Area Safety Door] Switches
Each feeder work area safety door is provided with a [Feeder Work
Area Safety Door] switch inside as shown below.
Fig. 1X55
Fig. 1X54 [Feeder Work Area Safety Door] Switches
[FEEDER READY] Buttons
4.1 Safety Switches
0210-004 44 AFO01EOPP