1OM-1050-002.pdf - 第51页

4.2.3 X/Y T able P .C.B. Detection Sensors When a P .C.B. is not positioned correctly on the X/Y table, these sen- sors are used to stop the machine. S en s o r N a me Symbol C o u n termeasures X/Y T able P .C.B. Detect…

100%1 / 145
4.2.2 Feeder Carriage Collision Error Detection Sensors
When some feeder carriage collide with each other, these sensors are
used to stop the machine.
Sensor Name Symbol Countermeasures
Carriage Collision 12
BPH57
Carriage Collision 23 BPH58
Carriage Collision 34 BPH59
4.2 Module Protection Sensors
Table 1X11
When one of the left sensors has detected an error,
the following measures are taken.
The power to drive Feeder Carriages #1, #2, #3,
and #4 is shut off.
The rotary turret stops after a cycle of operation.
Ref.: The rotary turret stops with its angle at
0° or 360°.
0301-003 48
AFO01EOPP
4.2.3 X/Y Table P.C.B. Detection Sensors
When a P.C.B. is not positioned correctly on the X/Y table, these sen-
sors are used to stop the machine.
Sensor Name Symbol Countermeasures
X/Y Table P.C.B. Detection (Fixed) BPH47
X/Y Table P.C.B. Detection (Movable) BPH49
4.2 Module Protection Sensors
Table 1X12
When one of the left sensors has de-
tected an error, the following mea-
sures are taken.
The power to drive the X/Y table is
shut off.
The rotary turret stops after a cycle
of operation.
Ref.: The rotary turret stops with its
angle at 0° or 360°.
0301-002 49
AFO01EOPP
Section 1
Scope
0307-003 1-A AFO01EOPP
This section explains the name and function of each sec-
tion and the mechanism of the surface mounting about the
component placement machine.