1OM-1050-002.pdf - 第80页
2.3.7 Ethernet LAN Data can be exchanged between the network terminal (option) and the machine in the Ethernet LAN system. Fig. 1A17-1 0207-001 1-21-2 AFO01EOPP 2.3 Operational Measures CAUTION • Do not exchange data thr…

2.3.6 Rear Service Panel
Fig. 1A17
*1 Selector Switch
This switch is used to select either the operation panel of the main
machine or the secondary operation panel for maintenance.
CAUTION
Keep the selector switch "OFF" during automatic op-
eration.
When the switch is turned "ON", the power will be
cut off.
*2 Connector for Secondary Operation Panel
This connector is used to connect the secondary operation panel
for maintenance.
*3 Ground Terminal for Wrist Band
The wrist band must be connected to this terminal for grounding.
ON OFF OPE-TAB
*1 Selector Switch
*2 Connector for Secondary
Operation Panel
*3 Ground Terminal
*3 for Wrist Band
0207-002 1-21-1 AFO01EOPP
2.3 Operational Measures

2.3.7 Ethernet LAN
Data can be exchanged between the network terminal (option) and the
machine in the Ethernet LAN system.
Fig. 1A17-1
0207-001 1-21-2 AFO01EOPP
2.3 Operational Measures
CAUTION
• Do not exchange data through Ethernet cabling
(Local Area Network) between the system and
a computer that is not provided with any viral
strategies.
Otherwise, viruses might enter the network, caus-
ing the machine to malfunction.
• Isolate the system without using Ethernet ca-
bling (Local Area Network) except for the speci-
fied functional operations.
Otherwise, the machine will break down.

2.4 Main Units
2.4.1 Feeder Carriages
Fig. 1A18
The carriages carry feeders for component supply.
The tape or bulk feeders can be installed on the feeder carriages. The
carriages move right and left to supply components.
WARNING
Never operate the machine with the feeder carriage
covers being open.
The feeder carriages are moved at high speed by
means of a strong motor.
It is very dangerous for a person or a thing to come
in contact with the moving section.
Components should be loaded on the tape or bulk feeders.
Refer to the instruction manual of the tape or the bulk feeders
for details.
WARNING
Those who wear an implanted pacemaker are not
allowed to work inside the carriage covers.
Strong magnets are used in the feeder carriage sec-
tions.
Therefore, the pacemaker may be affected by mag-
netism.
2.4 Main Units
Feeder
Feeder Carriage
0110-003 1-22 AFO01EOPP