1OM-1050-002.pdf - 第77页
2.3.5 Front Service Panel Fig. 1A16 *1 Working Lamp Switch This switch is used to turn on or off the working spot lamp. *2 Ground T erminal for W rist Band This terminal is used to clear a ground through the wrist band. …

*4 [ENABLE] Button
• When the [ON] button (entitled "MOVE") is pressed in the active operation
sheet, the lamp of the [ENABLE] button illuminates for two seconds. When
the [ENABLE] button is pressed with its lamp "ON", the machine performs
various operations selected in the operation sheets.
*5 [PNL CHANGE] Button
• This button is used to select either the front or the rear operation panel.
(a) The other operation panel can be selected by pressing the [PNL
CHANGE] button on the unavailable (invalid) side only when
the currently selected panel is not set in the "Operation Locked"
mode.
(b) While the LED of this button is ON, the followings become
available.
Rear Touch Screen
[START] Button
[STOP] Button
[ENABLE] Button
(c) The [STOP] button can be activated anytime regardless of the
[PNL CHANGE] button.
(d) When the panel operation is not locked and the [STOP] button
on the unselected operation panel is pressed, the operation
panel on the pressed button side becomes activated automati-
cally.
• When this button is pressed with the LED being "ON", only the rear opera-
tion panel becomes available in operations (Operation Locked) and the
[LOCK] lamps on both front and rear operation panels illuminate.
To cancel the "LOCK" mode, press this button again.
*6 [LOCK] Lamp
• While the lamp is ON, it indicates that the selected operation is locked.
• When the operation panel is operated from the unavailable side, the [LOCK]
lamp flickers.
To cancel the flickering of the lamp, press the [PNL CHANGE] button and
follow the steps to set the operation-lock mode again.
*7 Rear Touch Screen
• The operation windows will be displayed on the rear touch screen as well
as the front one.
Various types of operations become available by touching the buttons and
tabs on the screen.
2.3 Operational Measures
0207-004 1-19 AFO01EOPP

2.3.5 Front Service Panel
Fig. 1A16
*1 Working Lamp Switch
This switch is used to turn on or off the working spot lamp.
*2 Ground Terminal for Wrist Band
This terminal is used to clear a ground through the wrist band.
*3 Selector Switch
This switch is used to select either the operation panel "OFF" of the
main machine or the secondary operation panel "ON" for mainte-
nance.
CAUTION
Keep the selector switch "OFF" during automatic op-
eration.
When the switch is turned "ON", the power will be
cut off.
*4 Connector for Secondary Operation Panel
This connector is used to connect the secondary operation panel
for maintenance.
This connector is provided only for a service personnel.
ON OFF
LIGHT
FDD
CD-ROMD
OPE-TAB
*3 Selector Switch
*1 Working Lamp
Switch
*2 Ground Terminal
for Wrist Band
*5 Floppy Disk Drive
*4 Connector for Secondary
Operation Panel
*6 CD-ROM Drive
0207-004 1-20 AFO01EOPP
2.3 Operational Measures

*5 Floppy Disk Drive
The device data, the pattern program data, etc., can be saved on a
floppy disk.
The data on the floppy disk can also be loaded onto the machine.
CAUTION
• Do not use the floppy disk drive for any func-
tions other than the specified ones.
Otherwise, the machine may break down because
the program may be corrupted due to computer vi-
ruses or worms or may be changed in the hard disk
of the machine.
• Do not press the eject button of the disk drive
when the access lamp is ON. Otherwise, the data
may be corrupted, causing the machine to break
down.
*6 CD-ROM Drive
This is a device that can only read information from CD-ROM disk.
This is used to upgrade the system program.
CAUTION
• Do not use any CDs other than the provided
ones.
Otherwise, the machine may break down because
the program may be corrupted due to computer vi-
ruses or worms or may be changed in the hard disk
of the machine.
• Do not remove the inserted CD from the
drive while the lamp is "ON". Otherwise, the
data may be corrupted, causing the machine to
break down.
2.3 Operational Measures
0207-004 1-21 AFO01EOPP