00195193-02 SG D4 FSE en (1).pdf - 第125页

Services to the machine Power Supply Unit Naming Convention of Connectors and Cables S tudent Guide SIPLACE D4 (FSE) Services to t he machine EN 09/2006 11 8 6.2.1 Naming Convention of Connectors and Cables The SIPLACE D…

100%1 / 340
Services to the machine
Power Supply Unit
Student Guide SIPLACE D4 (FSE)
EN 09/2006 Services to the machine
117
Legend:
1. F1: 3x 230 V AC
SZ1: main contactor
MS1: Motor protection switch
S1: main switch
2. F2: 220 V AC for 5 V power supply
F4: 3x 140 VAC X/Y axes
SZ2,SZ3, SZ23: auxiliary contactors U,V,W for
X/Y servos
3. F5: 150 V DC star axis servo
F6: 40 V DC Z/DP axis servo
F7: 40 V DC CO table
F8: 40 V DC PCB handling (conveyor)
F9: 8 V DC CO table
F10: 48 V DC Vision illumination
F11: 24 V DC terminal strip distributor 2/4
F12: 24 V DC Microbox PC (MC)/control "ON"
(K1)
F13: 24 V DC Box PC (SR)/axis unit 1/2
F14: 24 V DC conveyor control (CC 301)/
monitors
Z2: discharge inductor
4. K1: protective contactor combination
Relay1: control ON - button
SZ4: control ON - software
FU: fuse 6.3 AT 220 VAC to GND
FV: fuse 6.3 AT 220 VAC to GND
FW: fuse 6.3 AT 220 VAC to GND
FBU: fuse 6.3 AT 220 VAC to GND
X1: feed in - terminal strip
BU1: service socket
Services to the machine
Power Supply Unit Naming Convention of Connectors and Cables
Student Guide SIPLACE D4 (FSE)
Services to the machine EN 09/2006
118
6.2.1 Naming Convention of Connectors and Cables
The SIPLACE D4 cables and leads are clearly labeled. Each cable, connector, distributor uses an exact
term, which is dedicated to the sections and units in question.
6.2.2 Assemblies in Sector 1
Placement
head - gantry 1
Placement
head - gantry 2
Placement
head - gantry 3
Placement
head - gantry 4
Designation a+ b+ c+ d+
Trailing cable distributor 03035887 aa ba ca da
Gantry distributor 03035888 ab bb cb db
Gantry head distributor 03038002 ac bc cc dc
Vision board eu fu gu hu
Hotlink filter lf mf nf of
Naming convention for cables and
connections in sector 1
Conveyor control ao
Terminal strip (voltage supply) X100
Connections (plug-in connectors) af
Vision DC/DC converter A1 qc
CAN Bus terminator for CO table qd
Services to the machine
Assemblies in Sector 2 Power Supply Unit
Student Guide SIPLACE D4 (FSE)
EN 09/2006 Services to the machine
119
6.2.3 Assemblies in Sector 2
Naming convention for cables and connections in sector 2
Terminal strip (voltage supply) X200
Connections (plug-in connectors) bf
CAN I/O module qc
CAN interface re
CAN Bus terminator for CO table rf
6.2.4 Assemblies in Sector 3
Naming convention for cables and
connections in sector 3
Terminal strip (voltage supply) X300
Connections (plug-in connectors) cf
CAN Bus terminator for CO table rd