Services to the machine Power Pack 5 V Power Supply Unit Student Guide SIPLACE D4 (FSE) EN 09/2006 Services to the machine 123 6.2.10 Po wer Pack 5 V 6.2.1 1 Power Supply for Axis Unit The power pack is fed from the prim…

Services to the machine
Power Supply Unit Voltages in the Power Supply Unit After Switching On
Student Guide SIPLACE D4 (FSE)
Services to the machine EN 09/2006
122
6.2.8 Voltages in the Power Supply Unit After Switching On
When the main switch is activated, the following voltages are generated, sent to the modules and
released or held ready for release:
6.2.9 Power Pack 24 V
Voltages Module State
250 VDC X/Y servo module not enabled
150 VDC Star servo not enabled
34 VDC PCB handling system Released up to SZ2
24 VDC tape cutter not enabled
34 VDC SZ1 main power inrush current enabled
52 VDC DC/DC converter main power supply enabled
52 VDC Camera illumination enabled
40 VDC Power fail A3 enabled
42 V DC Z/DP axes enabled
40 VDC Feeder table plate enabled
28 VDC monitor enabled
24 VDC fan enabled
230 or 115 or 240 VAC service socket independent of the main switch
NOTE:
The service socket can only be used if the placement system is connected to
the main power supply with a 5-conductor cable (L1, L2, L3, N, PE).
The power pack is fed from the primary side of the
transformer.
It is supplied via 3 phases.
Legend:
1. Main distributor (sector 2 X5)
Subdistributor (sector 4 X5)
2. K1 protective combination relay (A1+)
Micro box PC (machine controller X4)
3. Axis unit 1/2 (X8_7,X9_7)
Box PC (station computer X3)
4. Conveyor (X6_2)
Monitor 1/2 (X2_1,X2_3)
5. 3 phases
The data in brackets are for the output connector
plugs in the voltage supply rack unit.

Services to the machine
Power Pack 5 V Power Supply Unit
Student Guide SIPLACE D4 (FSE)
EN 09/2006 Services to the machine
123
6.2.10 Power Pack 5 V
6.2.11 Power Supply for Axis Unit
The power pack is fed from the primary side of the
transformer.
The 5 V power pack is fed after fuse F2, with one
phase (L1).
Legend:
1. 3-phase up to fuse
2. +5 V distributor sector 2 for cutter 2/3
3. +5 V distributor sector 4 (USB, video
multiplexer, cutter 1/4)
4. The data in brackets are for the output
connector plugs in the voltage supply rack
unit.
After activating the main switch, the axis unit is
supplied with power from the main power supply,
via X8 for axis unit 1 and X9 for axis unit 2. It is
supplied with 48 VDC and the following voltages
are generated:
+/-15 V and +/-15/5 V
This DC/DC converter generates the 5V and +/-
15V needed for the servo board and the axis
controller

Services to the machine
Power Supply Unit Voltage Supply for SIPLACE Vision Illumination
Student Guide SIPLACE D4 (FSE)
Services to the machine EN 09/2006
124
6.2.12 Voltage Supply for SIPLACE Vision Illumination
6.2.13 Power Supply Tape Cutter
6.2 - 4: Power supply tape cutter
The tape cutters are arranged in a parallel and a serial mode. The tape cutters in sector 2 and sector 3
are serial, tape cutters in sector 1 and sector 4 are also arranged in serial mode.
The pneumatic valves require 24 V, while the tape cutter control board is supplied with 5 V from the
power pack in the power supply unit.