3.2.3 Pneumatic Unit
The pneumatic unit is a fixed installation inside the machine and is located to the right of the middle
section of the machine, behind a flap. The pneumatic unit includes all electrical connections for control/
regulation of the compressed air supply.
3.2.3.1 Compressed Air Distributor Block
The pneumatic unit is used to prepare and distribute the compressed air required in the machine. The
pressure at the compressed air connection must be at least 4.5 bar.
The following pneumatic circuits are supplied with compressed air via the distributor block:
Gantries 1 - 4 (placement heads), vacuum generation: min. 4.5 bar
Conveyor system: 4.5 bar
Tape cutter for locations 1 - 4: 4.5 bar
Nozzle changer for locations 1 - 4: 4.5 bar
Feed-in units for the changeover tables: 4.5 bar
Bulkcase feeder for locations 1 - 4: 2.5 bar
Fine adjustment for the individual pneumatic circuits is performed directly at the pneumatic units, via the
adjustment valves.
Legend
1. Main compressed air connection with shutoff
valve and manometer
2. 4x connection for bulkcase feeder with
manometer, adjustable (2.5 bar), location 1-4
3. 4x connection for cutters, location 1 - 4
(4.5 bar)
2x connection for conveyor lifting table
4. 4x Connection for nozzle changer (4.5 bar)
5. 4x connection for docking/undocking CO table
(4.5 bar)
6. Electronic control valve for incoming pressure
5.0 bar.
7. 4x connection for gantries 1 - 4, vacuum
generation C&P head with shutoff valves
8. Compressed air filter
Overview
Power Supply Unit General Overview of Assemblies
Student Guide SIPLACE D4 (FSE)
EN 09/2006 Overview
49
3.2.4 Power Supply Unit
The main power supply unit is mounted on a compact rack unit and is located on the left of the middle
section of the machine. From outside, you can only see the red main switch.
A lockable door prevents access to the power supply.
3.2.4.1 Overview of Voltages in the Power Supply Unit
3.2 - 5: Power supply – view of right-hand side
Legend
1 Transformer 1 6 Power supply A2 (5 V/6.3 A)
2 Secondary terminal strip with fuses (output
voltage T1)
7 Power supply A1 (24 V/40 A)
3 Connector strip X2-X10, X12, X13 8 Line filter Z1 (input voltage)
4 Terminal strip X1 9 Front view (see following diagram)
5 Power fail board A3 10 Inrush current limiter (behind the cable duct)
Overview
General Overview of Assemblies Power Supply Unit
Student Guide SIPLACE D4 (FSE)
Overview EN 09/2006
50
Legend:
1. F1: 3x 230 V AC
SZ1: main contactor
MS1: Motor protection switch
S1: main switch
2. F2: 220 V AC for 5 V power supply
F4: 3x 140 VAC X/Y axes
SZ2,SZ3, SZ23: auxiliary contactors U,V,W for
X/Y servos
3. F5: 150 V DC star axis servo
F6: 40 V DC Z/DP axis servo
F7: 40 V DC CO table
F8: 40 V DC PCB handling (conveyor)
F9: 8 V DC CO table
F10: 48 V DC Vision illumination
F11: 24 V DC terminal strip distributor 2/4
F12: 24 V DC Microbox PC (MC)/control "ON"
(K1)
F13: 24 V DC Box PC (SR)/axis unit 1/2
F14: 24 V DC conveyor control (CC 301)/
monitors
Z2: discharge inductor
4. K1: protective contactor combination
Relay1: control ON - button
SZ4: control ON - software
FU: fuse 6.3 AT 220 VAC to GND
FV: fuse 6.3 AT 220 VAC to GND
FW: fuse 6.3 AT 220 VAC to GND
FBU: fuse 6.3 AT 220 VAC to GND
X1: feed in - terminal strip
BU1: service socket