Component handling S Feeders Setting up the feeder modules S tudent Guide SIPLACE D4 (FSE) Component handling EN 09/2006 250 10.4.2 Setting up the feeder modules 10.4.2.1 Preparing th e component feeder t able and S feed…

100%1 / 340
Component handling
Carrying out a walk-through inspection S Feeders
Student Guide SIPLACE D4 (FSE)
EN 09/2006 Component handling
249
separating plate will be offset or bent.
10.4.1.5 Using spindles for large tape reels
X Insert spindles into the separating plates when using large tape reels.
1. Guide rail for the separating plates
2. Tape container
3. Waste tape container
4. support bars for the separating plates
5. separating plate
NOTE: using spindles
We recommend that you use spindles if the tape reel diameter exceeds 15"
(381 mm)". This will ensure that the feeder modules operate reliably.
1. Component trolley
2. position of the spindles
3. separating plate
4. Spindle (enlarged)
Component handling
S Feeders Setting up the feeder modules
Student Guide SIPLACE D4 (FSE)
Component handling EN 09/2006
250
10.4.2 Setting up the feeder modules
10.4.2.1 Preparing the component feeder table and S feeder modules for set-up
X Clean the contact surface for the feeder module.
X Clean the contact surface on the component feeder table.
X Remove loose components from the component feeder table with a brush or use a vacuum cleaner
with appropriate nozzle.
X Remove any firmly attached components with the screwdriver.
1. S feeder module
2. centering pin
3. centering ball
4. component table
5. connecting cable for the S feeder module
CAUTION:
Avoid removing components from the component table with your fingers. You
may hurt yourself with tiny splinters of metal.
Component handling
Setting up the feeder modules S Feeders
Student Guide SIPLACE D4 (FSE)
EN 09/2006 Component handling
251
10.4.2.2 Inserting S feeder modules
First place the front of the feeder module (item 1), i.e. the side with the slotted foot, onto the component
feeder table (item 4) so that the centering pin (item 2) on the component feeder table slides into the slot
in the feeder module foot.
Then lower the back of the feeder module until the centering ball (item 3) disappears into the hole in the
feeder module.
Make sure that the feeder modules are placed correctly on the component feeder table to suit their width.
Check that the feeder module is firmly seated on the component feeder table by tapping the side of the
feeder module with your finger. You should not be able to move it.
Connect the feeder module plug to the socket beneath the location. The red dot on the plug must point
towards the red dot on the socket.
NOTE:
When you connect the feeder module, make sure that you use the right socket
for the location since the feeder module receives the control pulse via this
socket. The feeder module may not work correctly if it is not connected to the
right socket. The user manual for the feeder modules used will contain detailed
information on the assignment of plugs to sockets.
1. Feeder module, 30 mm wide
2. Feeder module, 45 mm wide
3. centering ball