Modular conveyor
Lifting table functions Conveyor Settings
Student Guide SIPLACE D4 (FSE)
EN 09/2006 Modular conveyor
275
X If the travel times are not inside the tolerance range or if error messages appear during production,
adjust the travel times as follows:
X Adjust the valve on the lifting table cylinder, so that you get the following values:
Lifting table up: 500ms +/-20ms
(without lifting table plate ~450 +/-20 ms DT / ~360 +/-20 ms ET)
Lifting table down: 480ms +/-20ms
(without lifting table plate ~550 +/-20 ms DT / ~600 +/-20 ms ET)
X If malfunctions occur during the downwards movement or if the board is shaken, reduce the lowering
speed accordingly.
Setting valve anticlockwise: Decrease the lifting table moving time
Setting valve clockwise: Increases the lifting table moving time
X The lifting table will be moved up and the travel
time will be displayed (see diagram).
X Press the
Actuate clamp
button again to
move the lifting table downwards and show the
travel time for the downwards movement.
Legend:
1. (3) adjust valve downwards
2. (4) adjust valve upwards
Modular conveyor
Conveyor Control Jumper Settings for Conveyor Control TSP 301
Student Guide SIPLACE D4 (FSE)
Modular conveyor EN 09/2006
276
11.4 Conveyor Control
11.4.1 Jumper Settings for Conveyor Control TSP 301
11.4 - 1: Jumper positions for conveyor control 301
Modular conveyor
Jumper Settings for Conveyor Control TSP 301 Conveyor Control
Student Guide SIPLACE D4 (FSE)
EN 09/2006 Modular conveyor
277
Legend
1 J7 CAN bus 1 terminating resistor 5 J6 CAN bus 2 terminating resistor (not used)
2 F6 Main Fuse TSP 301 6 J2, J1 successor/predecessor station
3 F1 - F5 Fuses for the conveyor motors 7 S4 DIL switch
4 J3 interference loop
Legend:
J1 predecessor station
J2 successor station
J3 interference loop
J6 CAN bus 2 terminating resistor (not used)
J7 CAN bus 1 terminating resistor
Legend:
1-2: This DIP switch sets the hardware ID 5 for
the SIPLACE D machine conveyors.
3: . (This DIP switch is for disabling/enabling
the clamping sensor.)
4-8: .