00195193-02 SG D4 FSE en (1).pdf - 第34页
Operational Safety Safety equipment Switches and buttons on the placement machine S tudent Guide SIPLACE D4 (FSE) Operational Safety EN 09/2006 34 2.4.1.3 Description of the functions Main power switch in the OFF positio…

Operational Safety
Switches and buttons on the placement machine Safety equipment
Student Guide SIPLACE D4 (FSE)
EN 09/2006 Operational Safety
33
2.4.1.2 Position of protective switches on the placement machine
2.4 - 2: Position of protective switches on the placement machine
Legend
1. Protective cover switch, location 1
2. Protective cover switch, location 2
3. Protective cover switch, location 3
4. Protective cover switch, location 4
5. Protective switch for the cover flap on the PCB conveyor input side
6. Protective switch for the cover flap on the PCB conveyor output side
7. PCB transport direction

Operational Safety
Safety equipment Switches and buttons on the placement machine
Student Guide SIPLACE D4 (FSE)
Operational Safety EN 09/2006
34
2.4.1.3 Description of the functions
Main power switch in the OFF position
The main power switch disconnects the three phases L1, L2, and L3 from the power supply.
Cable connection terminals L1, L2, and L3 of the Q1 main power switch
Z1 line filter
Service socket BU1
FBU automatic circuit breaker for the service socket
The color of all individual wires, which still carry potentially lethal voltages even if the main power
switch is switched off, is brown.
– Death, serious injury or considerable damage may result if these automatic placement systems
are handled incorrectly.
– Always follow the applicable accident prevention and DIN regulations (particularly DIN EN 60
204, part 1) and the applicable regulations in your own country.
– The safety door to the power supply must ONLY be opened by appropriately qualified and trained
personnel.
EMERGENCY STOP pushbutton, latching, with override protection to EN 418
The emergency stop button is red and latches in the ON position when pressed. When pressed, the
emergency stop button opens the switching contact of the emergency stop circuit - the protective
contactor combination (PCC K1) triggers. The link voltage (200 VDC) for the gantry axes and the link
voltage (150 VDC) for the star axes is switched off. The servo amplifiers for the DP and Z axes are still
supplied with 40 VDC. The signaling contact of the EMERGENCY STOP button will open and the
message
EMERGENCY STOP operated
will be shown on the screen. The following assemblies will
be disabled:
PCB conveyor
PCB clamping
Width adjustment
PCB stopper
Empty tape cutter.
See also:
J 2.4.3.1 Safety Circuit Function [J 35]
DANGER:
The following components still carry potentially lethal voltages even if the main
power switch is switched off:
NOTE:
Placement will be interrupted and can then be continued or canceled once the
machine is functional again.

Operational Safety
Position of Pushbutton for Docking and Undocking the Component Trolley Safety equipment
Student Guide SIPLACE D4 (FSE)
EN 09/2006 Operational Safety
35
2.4.2 Position of Pushbutton for Docking and Undocking the Component Trolley
2.4 - 3: Position of pushbuttons on the component trolley
Legend
1 Connection for component trolley T PCB transport direction
2 Pushbutton for raising the CO tables, with
feeder cover plate flap above