Axis dynamic Axis control Star Axis Axis control C&P head axes Student Guide SIPLACE D4 (FSE) EN 09/2006 Axis dynamic 167 7.5.3.1.2 Measurement Setup with SA T Box 7.5 - 2: Measurement setup with SAT box NOTE: For ch…

100%1 / 340
Axis dynamic
Axis control C&P head axes Axis control Star Axis
Student Guide SIPLACE D4 (FSE)
Axis dynamic EN 09/2006
166
7.5.3.1.1 Test setup with axis testbox
7.5 - 1: Test setup with axis testbox
Axis dynamic
Axis control Star Axis Axis control C&P head axes
Student Guide SIPLACE D4 (FSE)
EN 09/2006 Axis dynamic
167
7.5.3.1.2 Measurement Setup with SAT Box
7.5 - 2: Measurement setup with SAT box
NOTE:
For checking of the dynamics with the aid of the SAT-Box please use the official
Adjustment manual.
Axis dynamic
Axis control C&P head axes Axis control Star Axis
Student Guide SIPLACE D4 (FSE)
Axis dynamic EN 09/2006
168
7.5.3.1.3 Example for dynamic with the control signal of the Vnom. output
The star axis dynamics are checked in the permanent star step. A motor phase current (control signal 1)
is emitted at the V nominal output of the axis test box. The uncommutated current setpoint signal
(signal 3) shows increased friction axis values.
The positioning time for the star axis is 43 +/-3 ms for the C&P12.
SITEST:
X Select
C&P heads
==>
Select head
==>
Axis functions
==>
Select the star axis
==>
Star continuous operation
==> Entry: waiting period
500 ms
==>
Accept
.
X Press the START button is required.
Legend:
1. Current signal for axis adapter
2. Control signal (Axis testbox V nom.) current
target value: 2V/Div
3. Deviation of position 500mV/Div
4. End signal
Time basis: 10ms/Div
Positioning time: 43ms +/3ms
1 step = 30000 digits = 30 degrees
NOTE:
If the dynamics are significantly slower, check the friction blocks on the star and
the installation of the star in the drive's magnetic neutral position.