00195193-02 SG D4 FSE en (1).pdf - 第196页

Gantry Settings Description of the PCB boards on the Gantry S tudent Guide SIPLACE D4 (FSE) Gantry EN 09/2006 182 8.2 - 3: Gantry head distributor (from below) Legend 1 X1 flat ribbon cable 4 X4 not connected 2 X2 flat r…

100%1 / 340
Gantry
Description of the PCB boards on the Gantry Settings
Student Guide SIPLACE D4 (FSE)
EN 09/2006 Gantry
181
8.2.3 Description of the PCB boards on the Gantry
The boards on the gantry described below are basically identical and do not depend on the head
configuration of D1, D2 and D4 machines. The CAN Bus terminating resistor is fixed onto the gantry head
distributor.
8.2.3.1 Gantry head distributor
8.2 - 2: Gantry head distributor (from above)
Legend
1 X18 stepper motor DP axis
X19 stepper motor pick up position
X20 stepper motor reject position
6 X24 Test connector for „digital track signals for
X-axis“
2 X13/X14 flat ribbon cable to C&P head 7 X29 connector for Vision board
3 X11 test connector for CAN Bus, SPI Bus,
RS232
8 X10 connector for vacuum measurement
board
X12 motor for DP axis
X16 reference proximity switch (not in use)
X17 end position proximity switch for X-axis
(not in use)
X22/X21 one wire bus (not in use)
4 X30/X31 flat ribbon cable to P&P head for D1
(D4 not in use)
5 X5/X6 connector for 16 bit processor (TQM) 9 X26 connector for CO sensor
Gantry
Settings Description of the PCB boards on the Gantry
Student Guide SIPLACE D4 (FSE)
Gantry EN 09/2006
182
8.2 - 3: Gantry head distributor (from below)
Legend
1 X1 flat ribbon cable 4 X4 not connected
2 X2 flat ribbon cable 5 X15 connector for X-axis track signals
3 X3 flat ribbon cable 6 X9 flat ribbon cable
Gantry
Description of the PCB boards on the Gantry Settings
Student Guide SIPLACE D4 (FSE)
EN 09/2006 Gantry
183
8.2.3.1.1 Description of LEDs on the Gantry Head Distributor
Legend PCB labeling LED status Description
1 1-WIRE Not in use
CAN-INT OFF not used
POWER-FAIL OFF Error +24 V power supply
(from the main machine)
2 DC-ER OFF Error DC/DC converter
DC-EN ON Enable DC/DC converter
+SP-ER OFF Error +5V track encoder
+SP-EN ON Enable +5V track encoder
+15-ER OFF Error +15V
-15-OK ON -15V is OK
3.3-EN ON Enable +3.3V digital
3.3-ER OFF Error +3.3V digital
+5V-EN ON Enable +5 V digital
+5V-ER OFF Error +5V digital
+AN-ER OFF Error analog supply C167
3 V-OK ON Internal voltage monitoring of
eSW
V-OK OFF
ERROR OFF Error eSW
TEST Toggle Timer eSW in operation
4 +V-LS ON OK + 15V light barrier
+V-LS OFF Error +15V light barrier
Z-O ON Z-axis is up
Z-U ON Z down has switched
ERR-ZH OFF Overload SM feed-in
ERR-DP OFF Overload SM rotary axis
ERR-BA OFF Overload SM reject
LS-ZH ON Light barrier SM feed-in
LS-DP ON Light barrier SM rotary axis
LS-BA ON Light barrier SM reject