00195193-02 SG D4 FSE en (1).pdf - 第127页

Services to the machine Power Supply Unit Assemblies in Sector 4 S tudent Guide SIPLACE D4 (FSE) Services to t he machine EN 09/2006 120 6.2.5 Assemblies in Sector 4 Naming convention for cables and connecti ons in secto…

100%1 / 340
Services to the machine
Assemblies in Sector 2 Power Supply Unit
Student Guide SIPLACE D4 (FSE)
EN 09/2006 Services to the machine
119
6.2.3 Assemblies in Sector 2
Naming convention for cables and connections in sector 2
Terminal strip (voltage supply) X200
Connections (plug-in connectors) bf
CAN I/O module qc
CAN interface re
CAN Bus terminator for CO table rf
6.2.4 Assemblies in Sector 3
Naming convention for cables and
connections in sector 3
Terminal strip (voltage supply) X300
Connections (plug-in connectors) cf
CAN Bus terminator for CO table rd
Services to the machine
Power Supply Unit Assemblies in Sector 4
Student Guide SIPLACE D4 (FSE)
Services to the machine EN 09/2006
120
6.2.5 Assemblies in Sector 4
Naming convention for cables and connections in sector 4
Terminal strip (voltage supply) X400
Connections (plug-in connectors) df
CAN I/O module qb
CAN interface qe
CAN Bus terminator for CO table qf
6.2.6 Input voltage
6.2 - 2: Input voltage
Legend
S1 Main switch F1 Fuse for 24 V power pack
MS1 Motor protection switch F2 Fuse for 5 V power pack
SZ1 Main contactor and inrush current limiter
Services to the machine
Transformer 1 Power Supply Unit
Student Guide SIPLACE D4 (FSE)
EN 09/2006 Services to the machine
121
6.2.7 Transformer 1
The main task of transformer T1 is to supply power to the X/Y axes, protected by fuse F4, star axes by
fuse F5 and Z/DP axes by fuse F6. Contactors SZ2, SZ3 and SZ23 are a fixed part of the electrical safety
concept. In a fault event, e.g. open cover, the servos are disconnected from the energy.
The power supply provides the following voltages:
Secondary side of transformer (voltage before and after the rectifiers):
3x146 VAC for the servo amplifier of the X and Y axes (200 VDC)
3x24 VAC for the servo amplifier of the star axis. (150 VDC)
3x32 VAC for the servo amplifier of the Z/DP axis (40 VDC)
3x32 VAC for CO table and conveyor (40 VDC)
3x8 VAC for CO table (8 VDC)
3x40 VAC for the DC/DC converter and the power fail axis (48 VDC)
3x24 VAC for the inrush current limiter (34 VDC)
6.2 - 3: Overview of transformer T1