YesAX V3.1.2 - Software User Manual.pdf - 第285页

Specifications 29 -1 29 - S pecifications 29.1 Overview The Nordson YES TECH AXI Sy stems’ facility requi rem ents and spe cifications are list ed in Table 29 -1 . These specificat ions are int ended as a conv enient ref…

100%1 / 289
28-6 Trouble Shooting
28.5.1 SPC Data Logging
At the end of an inspection, the software may need to send inspection data to a database. The
error message below may be displayed if one or more field of data is too long.
The field can be the Serial number of the board (Max: 30 characters) the Work Order Number
(Max: 20), reference ID (Max: 20), PN (Max: 30) and Package Name (Max: 30). To resolve the
problem, the user should locate the extra long character field and then truncate it.
Specifications 29-1
29 - Specifications
29.1 Overview
The Nordson YESTECH AXI Systems’ facility requirements and specifications are listed in Table 29-1.
These specifications are intended as a convenient reference for installation, system relocation, planning
and operation. Meeting the requirements will ensure reliable operation and safety of the AXI system.
WARNING! CAUTION!
To ensure optimal performance and safety, it is necessary to install the coating
system in a facility that meets the requirements listed in this chapter. If you have
any questions, please contact Nordson YESTECH Technical Support.
29.2 Facility Requirements
The AXI Systems are designed for indoor use only. Table 29-1 provides general facility requirements for
the systems.
Table 29-1 Facility Requirements
Facility Requirements
System Footprint
83” x 83” x 81” (2110mm x 2110mm x 2060mm)
System Weight
4,842 lbs (2241 kg)
Air Input
30 psi MIN., 1/4” air hose. 2 CFM, 100 psi MAX
Main Power Supply
110VAC (220 optional) 50/60 Hz, 15 amps
Short Circuit Current
Rating (SCCR)
10kA
29-2 Specifications
29.3 System Specifications
Table 29-2 provides general specifications for the systems.
Table 29-2 System Specifications
Specifications
Throughput
Up to 4 sq. in./sec. > 500,000 components per hour
Max. Board Size
23” x 18” (580mm x 460mm)
Clearance
2” (50mm) top and bottom
Min. Component Size
0201; 01005 with high magnification option
False Calls
<500 PPM (<0.05% typical)
Defects Detected
Part: position, missing, wrong, polarity, skew, tombstone
Lead: bent, lifted, bridging
Solder: open, insufficient, short, solder balls
Material Handling
SMEMA, dual direction auto width conveyor, pass / fail signals, board
clamping
Lighting
Proprietary Fusion Lighting multi-angle LED
Imager
1 mega pixel color camera, 1 mega pixel X-ray camera
25, 12 or 6 micron pixel size
Noise
<70dBA, 76 db peak @ 1 M
Ambient Air Temp
41°F to 122°F (5°C to 50°C)
Max Relative Humidity
< 90% non-condensing
Altitude
5280 feet (1609 meters)
CE Certification
Yes (see
SECSII \ GEM Interface
Option