2- 10 Safety To lockout/tagout the electrical and pneumatic e nergy: 1. Shut down the computer. 2. Press the r ed EMO button ( Figure 2-4 ) to turn OFF the system. 3. Turn the Powe r switch to the OFF (O) position. Item …

100%1 / 289
Safety 2-9
2.11 Service Shutdown
Companies may differ in their Lockout/Tagout (LOTO) procedures and requirements, and it is the
responsibility of the end user to determine compliance with local safety procedures. The purpose of any
LOTO effort is to help avoid injury or AXI system damage due to unexpected energizing of equipment,
start up, or the release of stored energy during repair, maintenance, and operation of equipment.
Situations where LOTO practices may be employed on your AXI include:
Adjusting cables, belts, pulleys, or moving parts
Servicing bearings or motors
Troubleshooting, servicing, or replacing electronic components or assemblies
Troubleshooting, servicing, or replacing pneumatic components or assemblies
Situations where LOTO practices might not be required are when troubleshooting electrical, pneumatic,
or hydraulic components or assemblies that make de-energizing the whole system impractical.
Troubleshooting or servicing you AXI system while powered up and operating should only be
accomplished by fully trained and qualified personnel. There should always be a second person present
when performing maintenance on a system under power.
WARNING! All personnel working on or near the AXI system should know the location of all
electrical power supply sources.
WARNING! CAUTION!
Lock out and tag out electrical power before performing service or maintenance
work on the AXI system. Failure to do so could cause serious injury to the user
and/or serious damage to the cure module.
2-10 Safety
To lockout/tagout the electrical and pneumatic energy:
1. Shut down the computer.
2. Press the red EMO button (Figure 2-4) to turn OFF the system.
3. Turn the Power switch to the OFF (O) position.
Item
Description
1
EMO Button
2
System Power Switch
3
X-ray Power Switch
Figure 2-4 ON and EMO/Off Buttons
4. Disconnect the electrical plug from the facility power outlet.
5. Attach a prominent warning tag to the power cord with durable string.
This tag documents the name of the technician taking the equipment out of operation,
the date, and other facility-required information. It is a warning that the equipment
cannot be put back into operation until the authorized technician has removed the tag.
6. Perform maintenance, servicing, and troubleshooting as necessary.
NOTE Warning tags document the name of the technician taking the equipment out of operation,
the date, and other facility-required information. It is a warning that the equipment cannot be
put back into operation until the authorized technician has removed the tag.
1
2
3
Safety 2-11
2.12 Light Tower Status Lights
The AXI systems include a PLC-controlled light tower (Figure 2-5) that constantly shows the status of the
current operation.
Light Color
System Status
RED LEFT
The X-Ray is ON.
RED RIGHT
A system error is present. Refer to Section 23 - Customer
Support for recovery information.
YELLOW
The system is idle.
GREEN
The system is in operation and processing material.
GREEN and YELLOW
The system is in start mode and waiting to successfully process
the first substrate.
Figure 2-5 Light Tower Status Lights
RED
YELLOW
GREEN
RED