10-2 General Inspection Methodology
The Gain Offset Enhancement algorithm has two adjustable parameters that can be set in the
Image Gain and Offset Adjustment dialog.
10.2 Mark Inspection
Mark inspection is designed to verify the markings on the part. The default algorithm for mark
inspection is pattern matching. Other available algorithms are barcode reading, edge locator and
surface reference. There can be more than one mark inspection box per part.
After the Mark inspection box is created, you can display the Mark pop-up menu by pressing the
right mouse button while pointing at the inspection box.
General Inspection Methodology 10-3
Edit Mark Params..
Launches the Mark Parameter dialog. See 10.2.1 Edit Mark
Parameters.
Train Alternate
Train alternate template for Pattern Match algorithm.
Display Template
Display the templates trained.
Edit Alternate
Edit each alternate template. See 10.2.2 Edit Alternate
Set Search Area
Set the area on the image inside of which the software will
search for a match. This operation will change the Search
Margin parameter.
Train Dependent Tmp
Add a dependent template to the current alternate template.
Set Ref. Position
Allows user to set up a template position as being a (0, 0)
reference position.
Skip/Unskip
Allows user to either skip or unskip this mark inspection.
Move
Move the mark inspection box.
Delete
Delete this mark inspection box.
Test
Run the test on this inspection box.
Bar Code Params..
Available only when Bar Code is selected as the decision
algorithm menu item. See 10.2.3 Bar Code Parameters
Edge Locator Params..
Available only when Edge Locator is selected as the
decision algorithm menu item. See 10.2.4 Edge Locator
Parameters.
10-4 General Inspection Methodology
10.2.1 Edit Mark Parameters
Select Edit Mark Params from the Mark pop-up menu to open the Edit Mark Parameters dialog.
The Camera View group selects the view of the inspection. For 2D X-ray inspection, the Slice
View box must be unchecked and the Slice No. field doesn’t matter. For 3D inspection, the Slice
View box must be checked for slice view images and Slice No. must be specified.
The Lighting group selects the lighting. For X-ray views please select Side Light only.
The X-Ray Power Level field specifies the power level used for current inspection.
The PreProcess pull-down lists the available preprocessing algorithms and the Decision pull-
down lists the decision algorithms.
The Pass Score field, Polarity and Center Mark checkboxes and Search Margin field
parameters apply only to the Pattern Match algorithm. The Pass Score sets the sensitivity of the
acceptance. 100% means a perfect match. Acceptable pass scores for part inspection are between
40 to 80%. If Polarity is unchecked the software will accept images that are rotated 180 degrees
from the original image template. If Center Mark is checked the mark inspection box is always
at the center of the part.