Part 5 Chapter 3 Station Adjustments Edition 1.0 5-3-2 CP-6-series Mechanical Reference Rod Adjustment 1. Set an 8 x 4 mm tape feeder in the D1 position. 2. Press [SET] - [D pos.] - [1] - [CR] and the START button to mov…

100%1 / 331
Part 5 Chapter 3 Station Adjustments
Edition 1.0 5-3-1 CP-6-series Mechanical Reference
3. Station Adjustments
3.1 Station 1
Part Pick-Up
Station 1 is responsible for indexing the tape feeder and picking up parts.
3.1.1 Tape Feed Lever
The pitch lever is the mechanism that advances the feeder tape.
The vertical movement of this lever moves the tape to the pick-up location.
Two types of adjustment (rod and sensor adjustments) are required.
Adjustment rod
Roller
0.5 mm
Tape feed
lever
CP6M5014
Part 5 Chapter 3 Station Adjustments
Edition 1.0 5-3-2 CP-6-series Mechanical Reference
Rod Adjustment
1. Set an 8 x 4 mm tape feeder in the D1 position.
2. Press [SET] - [D pos.] - [1] - [CR] and the START button to move the feeder to
station 1.
3. Press [SET] - [MANUAL] - [I/O] and the EMERGENCY STOP button to take the
200 V down to 100 V.
WARNING
• Turn off the 200 V servo power before carrying out this work.
• Exercise extreme caution when working on the machine if the cam is
not at its origin (0 deg.). Recoil of the cam axis can endanger the
operator.
4. Use the cam handle to rotate the cam to 0°.
5. Switch the I/O (TAPE FEED SOL ON) setting ON.
6. Adjust the rod so that there is 0.5 mm clearance between the top of the pitch lever
and the roller. Access the rod from the cam box.
Retract sensor
Advance sensor
Tape feed lever
CP6M5015
Part 5 Chapter 3 Station Adjustments
Edition 1.0 5-3-3 CP-6-series Mechanical Reference
Advance Sensor Adjustment
1. When the dog is at the lower limit at cam angle 200°, ensure that the sensor is ON.
2. Set a dial gauge to the roller and adjust the sensor to go off 0.6 mm above the
lower limit.
Retract Sensor Adjustment
1. When the dog is at the upper limit at cam angle 0°, ensure that the sensor is ON.
2. Set a dial gauge to the roller and adjust the sensor to go off 0.3 mm below the
upper limit.
Dog upper limit
Dog lower limit
Dog
Retract sensor
0.3 mm
CP6M5017
0.6 mm
Dog upper limit
Dog
Dog lower limit
Advance sensor
CP6M5016